Mean Well RSP-500-5 Power Supply
5V 90A · 450W rated, not 500W · active PFC PF>0.95 · remote ON/OFF & remote sense · 18ms hold-up · 230 × 127 × 40.5mm

The highest-current 5V supply in the RSP family, and the only one with remote sensing — the feature that matters most when 90A has to travel down a cable at 5V — supplied by Excelled Display, LED display manufacturer and component supplier for global B2B integrators.

Mean Well RSP-500-5 5V 90A enclosed switching power supply with active PFC showing terminal block and closed case

Mean Well RSP-500-5 Power Supply at a Glance

What is it? The RSP-500-5 is the 5V model in the MEAN WELL RSP-500 series of enclosed single-output power supplies with active power factor correction. It accepts a full-range 85–264VAC input with no selector switch and delivers a regulated 5V DC output at up to 90A in a 230 × 127 × 40.5mm 1U case.

How much power does it actually deliver? 450W — not 500W. 5V × 90A = 450W. The three lowest-voltage models in this series share the same 90A ceiling, and at 5V that caps the output at 450W. It is the largest gap between series name and 5V reality in the RSP family.

What makes it different from every other 5V model in the range? Two built-in functions that appear together on no other RSP 5V model: remote ON/OFF control and remote sense. Remote sense compensates up to 0.3V of voltage drop on the load wiring. At 5V that is six percent of the entire rail — and at 90A over a realistic cable run, it is the difference between the modules receiving their rated voltage and not.

How is the fan controlled? Forced air cooling by a built-in DC fan — and on the 5V model the fan is always on. The datasheet states this explicitly: fan always on for 3.3~5V models, temperature-based fan ON/OFF control for 12~48V models. Do not expect the 5V variant to go quiet at idle.

How long does it hold its output up? 18ms at 230VAC and 14ms at 115VAC at full load. That is more than double the 8ms quoted on the RSP-150, RSP-200 and RSP-320 — the most substantial hold-up figure in the RSP 5V range and one of the clearest reasons to choose this model over the one below it.

What does it take in? A universal 85–264VAC input, or 120–370VDC, at 47–63Hz, with active inrush current limiting. Full-range input means no 115/230V selector switch.

What protections are built in? Overload at 105–130% of rated power using constant current limiting with automatic recovery — a different behaviour from the hiccup mode used on the RSP-200 and RSP-320 — plus over-voltage shutdown at 5.75–6.75V requiring a re-power, over-temperature shutdown with automatic recovery, and short-circuit protection.

What is it used for? LED display modules and cabinets on PFC-specified projects, factory control and automation apparatus, test and measurement instruments, laser-related machinery, burn-in facilities and RF applications. Configuration, MOQ and pricing from our sales team.

Mean Well RSP-500-5 5V 90A power supply angled view showing circular fan grille and output terminal block
Mean Well RSP-500 power supply front view with model label showing input range and output specification and both terminal blocks
Series Decoding

The RSP-500 Series: Eight Models, Three of Them Capped by the Same 90A

The RSP-500 series covers eight voltages from 3.3V to 48V. The three lowest share a 90A current ceiling, and no model in the series reaches exactly 500W — they range from 297W to 504W, with the higher-voltage models landing just above the name.

Model Output voltage Rated current Rated power Efficiency (typ.)
RSP-500-3.3 3.3V 90A 297W 81%
RSP-500-4 4V 90A 360W 83%
RSP-500-5 5V 90A 450W 84%
RSP-500-12 12V 41.7A 500.4W 88%
RSP-500-15 15V 33.4A 501W 88%
RSP-500-24 24V 21A 504W 89%
RSP-500-27 27V 18.6A 502.2W 89.5%
RSP-500-48 48V 10.5A 504W 90.5%
The 5V model carries the largest name-to-reality gap in the family. At 450W it is 50W below the series number — a ten percent shortfall. The 3.3V model is 203W below it. The higher-voltage models sit just above 500W and so match the name closely. If a project’s power budget was built by multiplying “500W” by the number of supplies, that budget is wrong for the 5V model by 50W per unit.

Efficiency follows the same pattern as the rest of the range: the 5V model is 84% against 90.5% for the 48V model. Delivering 450W at 84% efficiency means roughly 86W dissipated as heat inside the case — arithmetic from the datasheet efficiency figures, not a published loss figure — which is why this model has a fan that runs continuously.

Specifications

RSP-500-5 Specifications: Datasheet Parameters for the 5V 90A Model

Transcribed from the MEAN WELL RSP-500 specification sheet (RSP-500-SPEC, revision dated 2025-09-26) for the 5V model. Unless stated otherwise, readings are taken at 230VAC input, rated load and 25°C ambient.

Parameter RSP-500-5 specification
DC output voltage 5V, adjustable 4.5 ∼ 5.5V via SVR1 (+V ADJ.)
Rated current 90A, current range 0 ∼ 90A
Rated power 450W
Ripple & noise (max.) 150mVp-p at 20MHz bandwidth
Voltage tolerance ±2.0% (includes set-up tolerance, line regulation and load regulation)
Line regulation ±0.5%
Load regulation ±1.0% from 0% to 100% rated load
Set-up / rise time 1500ms, 80ms/230VAC; 3000ms, 80ms/115VAC at full load
Hold-up time (typ.) 18ms / 230VAC; 14ms / 115VAC at full load
Input voltage range 85 ∼ 264VAC universal full range, no selector switch; 120 ∼ 370VDC
Input frequency 47 ∼ 63Hz
Power factor (typ.) PF > 0.95 / 230VAC, PF > 0.98 / 115VAC at full load
Efficiency (typ.) 84% at 5V; the series spans 81% at 3.3V to 90.5% at 48V
Inrush current (typ.) 20A/115VAC, 40A/230VAC, with active inrush current limiting
Leakage current <2mA / 240VAC
Overload protection 105 ∼ 130% rated output power; constant current limiting, recovers automatically once the fault is removed
Over-voltage protection 5.75 ∼ 6.75V; shuts down the output, re-power required to recover
Over-temperature protection Shuts down output, recovers automatically once temperature falls
Remote control Built in. POWER ON: open or 0∼0.8VDC between RC+ (CN100 pin 4) and RC− (CN100 pin 3). POWER OFF: 4∼10VDC between the same pins
Remote sense Built in. Compensates voltage drop on the load wiring up to 0.3V
Fan control RTH2 50°C±10 fan on / RTH2 40°C±10 fan off — but fan is always on for the 3.3∼5V models; ON/OFF control applies to 12∼48V
Cooling Forced air cooling by built-in DC fan (fan ON/OFF control fosc 70KHz)
Working temperature −30 ∼ +70°C with derating (refer to the derating curve, horizontal mounting)
Working humidity 20 ∼ 90% RH, non-condensing
Storage −40 ∼ +85°C, 10 ∼ 95% RH
Temperature coefficient ±0.03%/°C (0 ∼ 50°C)
Vibration 10 ∼ 500Hz, 2G, 10 min per cycle, 60 min each along X, Y and Z axes
Withstand voltage I/P–O/P 3KVAC; I/P–FG 2KVAC; O/P–FG 0.5KVAC
Isolation resistance 100MΩ / 500VDC at 25°C, 70% RH
Dimensions (L×W×H) 230 × 127 × 40.5mm (1U) (Case No. 226A)
Weight / packing 1.3kg per unit; 9pcs / 12.7kg / 0.7CUFT per carton
MTBF 1372.4K hours min. (Telcordia SR-332); 187.9K hours min. (MIL-HDBK-217F at 25°C)
Warranty 3 years (manufacturer’s stated warranty on the datasheet)

One parameter is deliberately absent from that table. The RSP-500 datasheet quotes typical AC current in two grouped figures that do not map unambiguously onto individual models in the extracted specification, and we will not print a number we cannot attribute with confidence. If AC input current at a specific line voltage matters to your design, ask us and we will confirm it against the current datasheet revision for the exact model.

Remote Functions

RSP-500-5 Remote Sense: Why 0.3V Compensation Matters More at 5V

Remote sense is the reason to choose this model over the RSP-320-5, and it is the feature most often left out of reseller listings entirely. It works by measuring the voltage at the load rather than at the supply terminals, and adjusting the output to hold the load voltage correct.

The arithmetic that makes it necessary

The datasheet states the remote sense function compensates voltage drop on the load wiring up to 0.3V. On a 48V rail, 0.3V is six tenths of one percent — a detail. On a 5V rail it is six percent of the entire supply voltage, and six percent is the difference between modules receiving their specified voltage and running visibly dim at the far end of a run.

Situation Without remote sense With remote sense (0.3V compensation)
Short, heavy-gauge cable run Drop is small; module voltage close to nominal Supply trims to hold module voltage exactly at nominal
Longer run or lighter gauge Modules at the far end run below 5V and dim; the fault looks like a module problem Compensation corrects up to 0.3V of the drop automatically
Drop worse than 0.3V — Beyond the function’s limit. The datasheet caps compensation at 0.3V, so the cable still has to be sized properly
Remote sense is not a substitute for correct cable sizing. It compensates up to 0.3V and no further. Treat it as a correction for the last few percent of drop, not as permission to under-specify the conductor. Size the cable for the current first, enable remote sense second, and measure at the module input to confirm.

Wiring the sense lines

  • CN100 is a 4-pin connector — pin 1 is −S, pin 2 is +S, pin 3 is RC− and pin 4 is RC+. The mating housing is an HRS DF11-4DS or equivalent.
  • Connect −S to the negative terminal of the load and +S to the positive terminal, at the load end of the run rather than at the supply.
  • Twist the sense pair. The datasheet specifies that the +S and −S leads should be twisted together in a pair to minimise noise pick-up. Sense lines carry a signal, not power, and they are measuring a voltage that the supply will act on.
  • Never leave sense lines unterminated and connected. An open or reversed sense connection makes the supply regulate against a wrong reference. If remote sense is not being used, the datasheet’s default configuration applies.

Remote ON/OFF on the same connector

This model also has built-in remote ON/OFF control, driven electrically or by a dry contact between RC+ (pin 4) and RC− (pin 3). The logic is 0∼0.8VDC or open for power ON, and 4∼10VDC for power OFF. The datasheet’s function diagram shows an external supply driving the input at 6∼20mA through a switch.

Note that between the RSP-150-5, RSP-200-5, RSP-320-5 and RSP-500-5, the RSP-500-5 and RSP-150-5 have remote control and the RSP-200-5 and RSP-320-5 do not — and only the RSP-500-5 adds remote sense on top. If a control scheme switches supplies over a signal line, those are the two models in the 5V range that can do it natively.

Transient Behaviour

RSP-500-5 Hold-Up Time: 18ms and What It Actually Buys You

Hold-up time is how long the supply keeps its output in regulation after the input disappears. The RSP-500-5 quotes 18ms at 230VAC and 14ms at 115VAC at full load — more than double the 8ms on the RSP-150-5, RSP-200-5 and RSP-320-5.

RSP model at 5V Hold-up at full load Relative to a 50Hz mains cycle
RSP-150-5 8ms (230VAC / 115VAC) Under half a cycle
RSP-200-5 8ms (230VAC / 115VAC) Under half a cycle
RSP-320-5 8ms (230VAC / 115VAC) Under half a cycle
RSP-500-5 18ms / 230VAC; 14ms / 115VAC Nearly a full cycle at 230VAC

What 18ms does and does not cover

  • It covers more than twice as much as the models below it. A notch, a switching transient or a brief sag that would end the output on an RSP-320-5 is ridden through on an RSP-500-5.
  • It still does not cover a brownout. A generator changeover, a source transfer or a sustained undervoltage event runs to tens or hundreds of milliseconds. No supply in this range bridges those.
  • It is measured at full load. Hold-up falls as load rises, so the 18ms figure is the worst case at rated output, not the best case.
  • There is a difference between the two line voltages. 18ms at 230VAC against 14ms at 115VAC. On a 115V site, budget from 14ms.
  • If a screen must survive a real outage, that is a system requirement. It is solved with a UPS or a DC-side hold-up arrangement — not by choosing a supply, however good its hold-up figure. But if the choice is between two supplies and one holds up for more than twice as long, that is a genuine difference in behaviour on a noisy site.
The rise time is longer too. Set-up is 1500ms at 230VAC and 3000ms at 115VAC, with an 80ms rise time — against 50ms on the RSP-200 and RSP-320. Longer rise can actually be an advantage: a slower output ramp is gentler on the downstream capacitance of a large module array than a fast one. It also means the visible delay between mains-on and image is slightly longer, which is normal and not a fault.
Protection Behaviour

RSP-500-5 Overload Protection: Constant Current Limiting, Not Hiccup

This is a real functional difference from the other RSP 5V models, and it changes what a screen does when it is overloaded.

RSP model at 5V Overload range Protection type What the screen does
RSP-200-5 105∼135% Hiccup mode, auto-recovery Output shuts down and retries repeatedly — a visible flicker cycle
RSP-320-5 105∼135% Hiccup mode, auto-recovery Output shuts down and retries repeatedly — a visible flicker cycle
RSP-500-5 105∼130% Constant current limiting, auto-recovery Output holds at the current limit instead of switching off — modules stay lit but dim

Why constant current limiting is often the better failure mode on a screen

  • No on-off flicker cycle. Hiccup mode produces a repeating shutdown and restart, which on a video wall reads as a strobing fault. Constant current limiting produces a steady, dimmer image.
  • The screen stays diagnosable. A dim screen still shows which modules are lit, which helps locate a shorted module. A screen cycling on and off shows nothing useful.
  • The current is capped, so the supply is protected either way. Both behaviours prevent damage. The difference is what the operator sees while the fault exists.
  • But a dim screen can be mistaken for a brightness problem. If a screen on an RSP-500-5 is uniformly dim and the fault is not obvious, measure the DC current before assuming anything else — the supply may be sitting in current limit.
Over-voltage protection is the one that does not self-recover. OVP trips between 5.75V and 6.75V, shuts the output down and requires a re-power to recover. Overload and over-temperature both recover automatically; OVP does not. That asymmetry is the single most useful thing to know when a screen will not come back on after a fault.
Comparison

RSP-500-5 vs RSP-320-5 vs RSP-200-5: The 5V Ladder in Full

Four 5V models, one range. The higher you go the more current you get — but three other things change as well, and two of them only appear at the top of the ladder.

Parameter RSP-500-5 RSP-320-5 RSP-200-5
Output 5V / 90A 5V / 60A 5V / 40A
Rated power 450W 300W 200W
Cooling DC fan, always on at 5V DC fan, speed control Fanless
Remote ON/OFF Built in (CN100) Not provided Not provided
Remote sense Built in, 0.3V compensation Not provided Not provided
Hold-up time 18ms / 230VAC, 14ms / 115VAC 8ms 8ms
Overload behaviour Constant current limiting Hiccup mode Hiccup mode
Efficiency (typ.) 84% 83% 87%
Input range 85∼264VAC 88∼264VAC 88∼264VAC
Leakage current <2mA / 240VAC <1mA / 240VAC <1mA / 240VAC
Dimensions 230×127×40.5mm 215×115×30mm 215×115×30mm
MTBF (Telcordia) 1372.4K hrs 1826.4K hrs Not quoted on the revision held
Best for 90A at 5V with remote control and sensing 60A at 5V in a ventilated cabinet 40A at 5V with no moving parts

Four things the wattage difference does not tell you

  • Remote sense is unique to this model at 5V. If a cabinet has long DC runs at 5V and 90A, no other RSP 5V model can correct the resulting drop. That is a functional gap, not a specification detail.
  • Hold-up more than doubles. 18ms against 8ms on both models below. On a site with a noisy or unstable supply, this is the parameter that decides whether a screen blinks during a switching event.
  • The overload behaviour changes. This is the only RSP 5V model with constant current limiting; the two below use hiccup mode. What a screen looks like while overloaded is different.
  • Efficiency does not improve with size. 84% here against 87% on the fanless 200W model. Bigger output at low voltage means more heat, not less — and the fan that removes it runs continuously at 5V rather than cycling with temperature.
Thermal planning at this power level. At 84% efficiency, one RSP-500-5 at full load puts roughly 86W of heat into the cabinet — arithmetic from the datasheet efficiency figure. Three of them put roughly 258W into the same enclosure, with three fans drawing cabinet air across three boards. At this density, cabinet ventilation stops being a detail and becomes the constraint on the design. Note also that the RSP-500 series does not list an optional conformal coating, which the RSP-200 and RSP-320 series both do — in a dusty site that removes one mitigation the smaller models offer.
Sizing

How Many LED Modules Can One RSP-500-5 Power?

No supplier can answer this without knowing your module. The count depends on the maximum power rating of your LED module from its own datasheet, the number of modules on the supply, the thermal headroom you leave, and — on a 90A supply — the voltage drop down the DC run.

  1. Start from the real rating. 450W at 5V, which is 90A.
  2. Apply a load ceiling. A common planning rule in LED cabinet builds is to keep continuous load at or below about 80% of rated output — roughly 360W, or 72A, on an RSP-500-5. This is an engineering convention rather than a MEAN WELL figure; confirm it against your own project’s thermal and warranty conditions.
  3. Divide by the module’s maximum power, taken from the module datasheet rather than a marketing page — full white is the condition a screen is commissioned under.
  4. Check the derating curve at real cabinet ambient. If the site is above 2000m, the datasheet applies an ambient derating of 5°C per 1000m for fan models.
  5. Size the DC conductor for 72A and then enable remote sense. Remote sense corrects up to 0.3V of drop; it does not excuse an undersized cable.
  6. Plan the heat. Roughly 86W per supply at full load has to leave the cabinet, and the fan is always on at 5V.

Worked as an Illustrative Example — substitute your own module figures; these numbers are for the arithmetic only:

Step Illustrative calculation
Supply rating 450W / 90A at 5V
Usable at 80% planning ceiling 360W / 72A
Module maximum power (illustrative) 25W per module
Modules per supply (360 ÷ 25) 14 modules, with 10W of the usable budget unspent
Heat into the cabinet at that load ≈69W at 84% efficiency — multiplied by the number of supplies in the cabinet

Parallel operation is not a function this model provides. If the screen outgrows one supply, split the cabinet into independently supplied sections rather than paralleling two RSP units. For the control and signal side of the same cabinet, the LED control system collection covers how sending cards, receiving cards and processors are powered and wired alongside the supplies.

Wiring

RSP-500-5 Wiring: TB1, TB2 and the CN100 Function Connector

The RSP-500-5 uses two separate terminal blocks plus a function connector — a different arrangement from the single 9-pin block on the RSP-200 and RSP-320, and one that has to be read correctly.

Block Pin Assignment Practical note
TB1 — AC input 1 AC/L — live Mains live input
2 AC/N — neutral Mains neutral input
3 FG — frame ground Bond to the cabinet earth; do not omit
TB2 — DC output 1 ∼ 3 DC OUTPUT −V Three terminals, shared negative rail
4 ∼ 6 DC OUTPUT +V Three terminals, shared positive rail
CN100 — functions 1 −S — negative sense Connect to the negative terminal of the load
2 +S — positive sense Connect to the positive terminal of the load; twist with −S
3 RC− — remote control return Return for the RC+ signal
4 RC+ — remote control input 0∼0.8VDC or open = ON; 4∼10VDC = OFF

Mean Well RSP-500 power supply output terminal block view showing terminal screw arrangement and model label for wiring identification

There is no input voltage switch to set

The RSP-500-5 is full-range 85–264VAC by design, unlike the LRS-family supplies which carry a 115/230V selector that ships in one position and destroys the unit if mains is applied in the wrong one. Note the range starts at 85VAC rather than the 88VAC of the RSP-200 and RSP-320 — a marginally wider low-line tolerance.

Split the load across the output terminals

At 90A, this is not optional. Use all three +V and all three −V terminals, or at minimum two per rail, and keep the DC run to the first module as short as the cabinet allows. At this current, terminal contact resistance and local heating become the practical limits rather than the supply’s regulation.

Leave the airflow path clear — the fan never stops

The mechanical drawing marks the air flow direction. Because the 5V model’s fan runs continuously rather than cycling with temperature, there is no idle period during which the supply tolerates being boxed in. Keep the intake and exhaust clear, mount horizontally as the derating curve specifies, and do not stack units tight against each other. Mounting is by 5 × M4 holes at 4mm depth, with additional M4 fixings on both sides.

Mean Well RSP-500 power supply mechanical drawing showing 230 by 127 by 40.5mm 1U dimensions mounting hole positions terminal blocks and fan opening

The same wiring discipline applies to the control hardware inside the cabinet. Our guides to the MCTRL660 LED display controller and the Colorlight X2 LED video processor cover the signal side, and the Huidu HD-A5 LED display player covers standalone playback for screens that run without a PC.

Compliance

RSP-500-5 Certifications and EMC: Class B with EN61000-6-2 Immunity

The RSP-500-5 carries the modern safety set and a broader immunity listing than the models below it in the range.

Item Detail from the RSP-500 datasheet (revision dated 2025-09-26)
Safety standards UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004, CCC GB4943.1, BSMI CNS15598-1, BIS IS13252(Part1):2010 / IEC 60950-1:2005 approved
EMC emission Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2, -3, EAC TP TC 020, GB/T 9254, CNS15936 Class B
EMC immunity Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, EAC TP TC 020
Withstand voltage I/P–O/P 3KVAC; I/P–FG 2KVAC; O/P–FG 0.5KVAC
Isolation resistance I/P–O/P, I/P–FG, O/P–FG: 100MΩ / 500VDC at 25°C, 70% RH
MTBF 1372.4K hrs min. Telcordia SR-332 (Bellcore); 187.9K hrs min. MIL-HDBK-217F (25°C)
EN61558-1/2-16 Not listed on this series datasheet

Why EN61000-3-2 is the line that matters commercially

EN61000-3-2 is the harmonic current emissions standard, and it is the reason the RSP family exists alongside the LRS family. MEAN WELL’s LRS datasheets state plainly that those units do not meet the harmonic current requirements of BS EN/EN61000-3-2 and set out conditions under which they should not be used in the European Union. The RSP-500 datasheet carries no such restriction — it lists compliance, because the active PFC stage is what makes compliance possible.

Two certification points to check rather than assume

  • EN61558-1/2-16 is not on this datasheet at all. On the RSP-320 datasheet those approvals are listed for 12V-or-higher models only; on the RSP-500 datasheet they do not appear. If a tender names EN61558, this series does not satisfy it and that has to be resolved before the specification is fixed.
  • The EMC tests are component-level. MEAN WELL specifies this unit as a component to be installed into final equipment and states that the final equipment must be re-confirmed as still meeting the EMC directives, referring to the manufacturer’s own EMI testing guidance for component power supplies. An RSP-500-5 on a bench is a certified component; inside a screen it is part of a system whose EMC must be validated in its own right.
Confirm the standard against the current revision. Datasheet revisions are dated and certificates are issued per model and revision. We work from the revision we hold — for this model, 2025-09-26 — and we say so rather than implying a certification we have not seen. On EU-bound and Korean-bound projects we confirm supply selection against the destination market’s harmonic and EMC requirements at the quotation stage: tell us the destination country and the total cabinet input power and we will confirm which family meets it.
Fit

When the RSP-500-5 Is the Wrong Power Supply

A page that cannot tell you when not to buy something is a catalogue entry, not advice. The RSP-500-5 is the right answer for 5V work at 90A where PFC is required and the cabinet can be ventilated, and clearly wrong in the following cases:

Situation Why the RSP-500-5 does not fit
Any requirement for silence or a no-moving-parts design The 5V model’s fan is always on, not temperature-controlled. The fanless ceiling at 5V in this range is 40A / 200W, at the RSP-200-5.
Sealed, unventilated enclosure The rating assumes forced airflow, and at 5V the fan never stops to give the supply a cooler interval. A sealed box recirculates heated air through a continuously running fan.
Dusty site needing conformal coating The RSP-500 series does not list an optional conformal coating, though the RSP-200 and RSP-320 series both do. At 5V that removes one mitigation — the RSP-320-5 may be the better fit in a contaminated environment.
A tender that names EN61558-1/2-16 Not listed on this series datasheet at all. Resolve before fixing the specification.
5V load above 450W per supply section The 90A ceiling is the limit of this model and the top of the 5V range in the RSP family. Split the cabinet into separately supplied sections.
Power budget assumes 500W per supply The 5V model is 450W — a 50W shortfall per unit. Recalculate the budget and the supply count before ordering.
No PFC or harmonic requirement, and cost decides PFC is much of what you are paying for. An LRS-600-5 gives 500W of 5V for less money where nothing in the specification demands PFC.
Power budget assumes “up to 90.5%” efficiency That figure is the 48V model. The 5V model is 84%, and its waste heat at full load is roughly 86W per supply.
Modules that require 4.2V or 3.3V The 5V model adjusts only between 4.5V and 5.5V. RSP-500-3.3 and RSP-500-4 cover the lower rails.
A cabinet with no room for a 40.5mm-tall supply This model is 230×127×40.5mm against 215×115×30mm for the RSP-320-5. It is both wider and 10.5mm taller, which can rule it out of a tightly packed cabinet regardless of its electrical fit.

Where the power supply is the wrong component to be choosing at all, the constraint is usually elsewhere in the system. On the indoor product side, pages such as the P3.91 rental LED display and the P2.5 indoor LED display set out the module-level specifications those decisions start from.

Troubleshooting

RSP-500-5 Troubleshooting: Dim Output, Latched Shutdown and Sense Faults

On this model the constant-current-limiting overload behaviour adds a symptom that does not appear on the RSP-200-5 or RSP-320-5, and the remote sense function adds a class of fault all of its own. Work through these in order.

The whole screen is uniformly dim but still running

  • Possible cause: the supply is sitting in constant current limiting at 105–130% of rated power. Unlike the hiccup-mode models below it, this supply does not switch off — it holds at the current limit, so the output voltage sags and the screen dims.
  • How to check: measure DC current at the output. If it is pinned at the limit rather than tracking load, the supply is limiting.
  • Fix: find the overload — a shorted module, a wiring fault or simply too many modules on the supply — and correct it. Do not compensate by turning the output adjustment up; the supply will still limit.

No output at all, and it stays off after a power cycle

  • Possible cause: over-voltage protection has latched. OVP on this model shuts the output down and requires a re-power to recover, unlike the overload and over-temperature protections, which both recover automatically.
  • Also check the remote control input. If RC+ and RC− are being driven between 4 and 10VDC, or if the wiring to CN100 is disturbed, the supply is being told to switch off. A remote-control fault looks exactly like a supply failure.
  • How to check: disconnect the load and re-power. If the output returns, the trip was load-related. Then verify the voltage between RC+ (pin 4) and RC− (pin 3) with the control circuit in its intended state.
  • Fix: correct what drove the output above 5.75–6.75V, or correct the remote-control signal, before reconnecting.

Output voltage is wrong at the supply but correct at the load, or vice versa

  • Possible cause: remote sense is active and is regulating against the load terminals rather than the supply terminals. This is correct behaviour, not a fault.
  • How to check: measure at both ends. With sense connected, the load voltage is the one being held correct and the supply terminal voltage will read higher by the amount of the drop.
  • Fix: none needed if the load voltage is correct. If the drop exceeds 0.3V, the sense function has reached its compensation limit and the cable has to be resized.

The screen behaves erratically and the sense wiring is long

  • Possible cause: untwisted or poorly routed sense lines picking up noise. The datasheet specifies the +S and −S leads be twisted in a pair for exactly this reason.
  • How to check: inspect the routing of the CN100 sense pair. If it runs alongside high-current output cables without being twisted, that is the likely source.
  • Fix: twist the sense pair, keep it away from the output conductors, and re-terminate. This is a low-cost fix that is frequently overlooked.

Output drops out and recovers on its own, repeatedly

  • Possible cause: over-temperature protection. Note that this is not the overload behaviour on this model — overload limits current rather than switching off, so a supply that switches off and back on is responding to temperature, not current.
  • How to check: measure cabinet ambient and case temperature, and confirm the fan is actually turning. At 5V the fan should run continuously.
  • Fix: restore airflow. If the fan has failed, the supply has no reserve — the rating depends on forced airflow and the fan is a wear item on a decade-long installation.

The screen takes two to three seconds to come on after mains is applied

  • Possible cause: nothing is faulty. Set-up is 1500ms at 230VAC and 3000ms at 115VAC, with an 80ms rise time — slightly slower than the 50ms rise on the models below.
  • How to check: measure the delay from mains applied to output stable and compare with the datasheet figure for the site voltage.
  • Fix: no fix required if the delay matches specification. If control logic assumes supplies are ready sooner, adjust the sequence timing rather than replacing hardware.
Downloads

RSP-500-5 Datasheet and Series Documentation

The documents below are the manufacturer’s own files, hosted by MEAN WELL. They are the reference we work from, and the correct place to verify any specification quoted on this page — including the remote sense and fan-control behaviour discussed above.

Document What it covers
RSP-500 series datasheet (PDF) Full specification table for all eight voltage models, derating curve, block diagram, mechanical drawing, terminal pin assignment and the CN100 function manual for remote control and remote sense
RSP-500 series product page All voltage variants with their individual model datasheets and certificates
Installation manual Manufacturer installation guidance for the RSP enclosed series
EMI testing of component power supplies The manufacturer’s own guidance on re-confirming EMC when a component supply is installed into final equipment

Mean Well RSP-500 power supply installed inside a cabinet with red and black DC output wiring connected showing real installation form

That photograph shows a unit installed in a cabinet with output wiring landed — a real installation rather than a studio shot. It shows the wiring form and the mounting position; it is not a named project reference and we do not present it as one. MEAN WELL also prints a serial number on each unit that can be traced on the manufacturer’s own website, which is the authoritative way to confirm a batch’s provenance and production date — more reliable than any listing photograph, including ours.

FAQ

Mean Well RSP-500-5: Frequently Asked Questions

QHow many watts is the Mean Well RSP-500-5?

450W, not 500W. At 5V and 90A the output is 450W, which is 50W below the series name. The three lowest-voltage models in the RSP-500 series share a 90A current ceiling, and at 5V that caps the output at 450W.

QDoes the RSP-500-5 have remote ON/OFF control?

Yes. It has built-in remote ON/OFF control on connector CN100: 0 to 0.8VDC or an open circuit between RC+ (pin 4) and RC- (pin 3) turns the output on, and 4 to 10VDC turns it off. The input can be driven electrically or by a dry contact.

QWhat is remote sense and does the RSP-500-5 have it?

Yes, and it is the only RSP 5V model that does. Remote sense measures the voltage at the load rather than at the supply terminals and adjusts the output to hold the load voltage correct, compensating up to 0.3V of voltage drop on the load wiring. On a 5V rail, 0.3V is six percent of the supply voltage.

QDoes the fan on the RSP-500-5 run all the time?

Yes. The datasheet states the fan is always on for the 3.3V to 5V models, while the 12V to 48V models use temperature-based ON/OFF control at 50 degrees Celsius on and 40 degrees off. The 5V model should not be expected to run silently at idle.

QWhat is the hold-up time of the RSP-500-5?

18 milliseconds at 230VAC and 14 milliseconds at 115VAC, at full load. That is more than double the 8 milliseconds quoted on the RSP-150-5, RSP-200-5 and RSP-320-5. It rides through transients and notches but still does not cover a brownout or a generator changeover.

QWhat is the difference between the RSP-500-5 and the RSP-320-5?

Current, remote functions, hold-up time and overload behaviour. The RSP-500-5 delivers 90A and 450W with built-in remote ON/OFF and remote sense, 18ms hold-up and constant current limiting. The RSP-320-5 delivers 60A and 300W with no remote functions, 8ms hold-up and hiccup-mode overload.

QHow do I wire the RSP-500-5 terminal blocks?

TB1 is the 3-pin AC input: pin 1 AC live, pin 2 AC neutral, pin 3 frame ground. TB2 is the 6-pin DC output: pins 1 to 3 are DC negative and pins 4 to 6 are DC positive. CN100 is a 4-pin function connector: pin 1 negative sense, pin 2 positive sense, pin 3 RC negative, pin 4 RC positive.

QDoes the RSP-500-5 have power factor correction?

Yes. It has a built-in active PFC function with a typical power factor above 0.95 at 230VAC and above 0.98 at 115VAC at full load, and the datasheet lists compliance to BS EN/EN61000-3-2 and EN61000-3-3.

QDoes the RSP-500-5 need a 115V or 230V selector switch set?

No. It accepts a universal 85 to 264VAC input with no selector switch, and also accepts 120 to 370VDC. The low-line figure of 85VAC is marginally wider than the 88VAC of the RSP-200 and RSP-320 models.

QWhat is the efficiency of the RSP-500-5?

Typical efficiency is 84% at the 5V output, measured at 230VAC input and rated load. The series spans 81% at the 3.3V model up to 90.5% at the 48V model, so the “up to 90.5%” headline figure does not apply to this model.

QWhat is the overload protection behaviour of the RSP-500-5?

Constant current limiting at 105 to 130% of rated output power, recovering automatically when the fault is removed. This differs from the RSP-200-5 and RSP-320-5, which use hiccup mode. In current limit the output voltage sags and the screen dims rather than switching off.

QCan the RSP-500-5 be used in a sealed or dusty enclosure?

A sealed enclosure is not suitable because the rating assumes forced airflow and the fan runs continuously at 5V, recirculating heated air. For dusty sites, note that the RSP-500 series does not list an optional conformal coating, though the RSP-200 and RSP-320 series both do.

Get RSP-500-5 Pricing for Your LED Display Project

Tell us your module voltage, the 5V load per cabinet, the length and gauge of the DC run, whether the control scheme needs to switch supplies over a signal line, and the cabinet’s ventilation arrangement. We will confirm the supply configuration, whether remote sense should be enabled, the quantity per screen and the delivered price. If your project has a harmonic or certification requirement, mention the destination country and we will confirm the compliant option in the same quotation.

Excelled Display supplies MEAN WELL power supplies alongside the modules, cabinets and control hardware they run with, so the power budget, the DC voltage drop and the screen specification are confirmed together rather than in isolation. For the rest of the chain, see the LED control system collection, the outdoor LED display range and the LED display manufacturing process behind them.

Related reading: Mean Well RSP-320-5 power supply · Mean Well RSP-200-5 power supply · Mean Well RSP-150-5 power supply · Mean Well LRS-600-5 power supply · MCTRL660 LED display controller


Scroll to Top

Contact Us Now!

Thank You for Your Inquiry!

 Our LED display expert will contact you within 12 hours.

You can also contact us directly: +86 18569492693 ;excelledscreens@gmail.com