NovaLCT screen configuration is the step that turns a stack of LED cabinets into one addressable canvas. Before a wall shows anything useful, three facts have to be correct inside the software: how many cabinets sit in each row and column, what pixel resolution each cabinet drives, and which Ethernet port feeds which cabinet. NovaStar’s sending card stores those answers, and NovaLCT is the tool that writes them.
Short answer: NovaLCT screen configuration runs in four steps on a Windows PC. Step 1 sets the graphics card to 100% scaling and the screen’s native resolution. Step 2 matches the sending card’s input resolution and refresh rate to that graphics output. Step 3 loads the receiving card parameters from the RCFGX file your supplier provides and sends them to every card. Step 4 enters the cabinet rows and columns, assigns each cabinet to an Ethernet port, and sends the connection map to hardware. Log in first through User > Advanced Synchronous System User Login with the default password admin.
Excel LED Display runs this sequence on every NovaStar-controlled screen before it leaves the factory, and the export from that session — RCFGX, screen connection file and a photo of the final map — travels with the cabinets. The steps below are the same order our technicians use, written so an installer receiving one of our LED displays can verify the work rather than rebuild it.
What Is NovaLCT Screen Configuration and Which Screens Need It?
NovaLCT screen configuration is the process of defining, inside NovaStar’s Windows configuration tool, how the physical cabinets of an LED display map onto the pixel canvas produced by the sending card. It decides three things at once: which cabinet occupies which position in the image, how many pixels each receiving card drives, and which output port carries the signal to that cabinet.
NovaLCT itself is the engineering front end for synchronous NovaStar systems — screens that mirror a live video source through a sending card or video processor. That covers the MCTRL sending box line, the VX all-in-one controllers, and the receiving cards inside the cabinets. It is not the right tool for three adjacent jobs:
- Content publishing to a Taurus media player is ViPlex Express or ViPlex Handy, not NovaLCT.
- Player-based screens built on asynchronous control use SmartLCT or the player’s own wizard for cabinet service.
- MX2000 Pro and MX6000 Pro controllers belong to the COEX generation and are configured in COEX VMP instead.
If you are still deciding which tool covers your project, the NovaStar software guide maps the whole family first. If your screen is driven by an MCTRL or VX controller, the four steps below are the complete path. If you are instead weighing configuration software against publishing software, our SmartLCT vs ViPlex Express comparison separates the two jobs.

What Should You Collect Before Starting NovaLCT Screen Configuration?
Most failed first sessions fail before the software opens, because one of five numbers is missing or wrong. Collect these first; every one of them is printed on a datasheet or a site drawing.
| What you need | Where it comes from | Worked example |
|---|---|---|
| Cabinet pixel resolution | Cabinet size in mm divided by pixel pitch | 640 / 2.5 = 256 px wide, 480 / 2.5 = 192 px high |
| Cabinets per row and per column | Site drawing, counted in cabinets not modules | 6 columns × 4 rows = 24 cabinets |
| RCFGX file | Supplied with the cabinets, one file per cabinet build | P2.5-640×480-MRV328.rcfgx |
| Ethernet ports available | Controller datasheet | 2 ports on an MCTRL300 LED display controller |
| Cabling order on site | Photo of the daisy chain taken after hanging | Port 1 feeds cabinets 1–12, port 2 feeds 13–24 |

How Do You Set the Graphics Card Before NovaLCT Configuration?
The graphics card step is where a lot of walls go wrong, because Windows is happy to scale an image and the LED screen will faithfully show the scaled result. NovaLCT compares two numbers — Sending Card resolution and Graphics Output resolution — and while they differ, the wall cannot be pixel-for-pixel.
- Set Windows display scaling to 100%. A laptop at 125% or 150% reports a logical resolution that no longer matches the physical pixels the LED screen receives.
- Set the LED screen’s resolution to its native pixel size. A 1,536 × 768 wall should be driven at exactly 1,536 × 768, not at 1,920 × 1,080 with the content letterboxed.
- Set the refresh rate to 60 Hz. This is the input refresh at the graphics card, separate from the LED refresh rate you tune later on the receiving cards.
- Choose extended rather than duplicate when the operator needs to work on the PC while the wall runs. Duplicate is fine for a single-purpose playback PC.
- Turn off GPU scaling and overscan in the graphics driver control panel, so the card passes pixels through untouched.
Five settings decide whether the rest of the configuration can work:
- Graphics output must equal the canvas — any mismatch shows up as a stretched or cropped image no matter how correct the cabinet map is.
- Rows and columns count cabinets, not modules — the single most common first-time error in screen connection.
- The RCFGX must match the exact cabinet build — a file from a different module or driver IC will load without complaint and light the wall incorrectly.
- Port loading must stay inside the pixel budget — an over-loaded port shows tearing or a dropped section under motion.
- Both the parameter set and the map must be sent to hardware — saving on the PC alone changes nothing on the wall.
How Do You Configure the Sending Card in NovaLCT?
NovaLCT is a Windows-only application and runs on Windows 7 and later. Install it, connect the PC to the sending card by USB or Ethernet, and power the controller before opening the program.
Log in through User > Advanced Synchronous System User Login and enter the default password admin. The same menu offers a demo mode for practising without hardware and a media player login for asynchronous devices; neither is needed for a synchronous wall. With a single sending card connected, the communication port field can stay on its default value.
Official NovaStar NCE training course: NovaLCT basic configuration, 26 minutes, covering the sending card, receiving card and screen connection tabs.
Open Screen Configuration, choose Configure Screen, and continue to the three tabs. The first tab, Sending Card, holds the input settings:
- Video input source — HDMI, DVI or DP, matching the cable actually plugged into the controller.
- Source resolution — the canvas size, or a custom value if the wall is not a standard resolution.
- Refresh rate and bit depth — 60 Hz and 8-bit cover most installations; higher bit depth costs bandwidth.
Press Set, then Refresh, and confirm that the Sending Card and Graphics Output readouts agree. Only after they match should you press Save. If the two numbers disagree, return to the graphics card settings before touching anything else — the sending card is faithfully reporting what it receives.
How Do You Configure the Receiving Card in NovaLCT?
The second tab, Receiving Card, is split into module information, cabinet information and performance settings. Cabinet information is the group that matters most, because it describes what the receiving card is actually driving: the cabinet’s pixel width and height, the module layout inside it, and the scan mode.
You rarely type these by hand. The supplier ships an RCFGX file for each cabinet build, and the correct path is:
- Click Load from File and select the RCFGX that matches your cabinet.
- Review the cabinet information that appears and confirm it against the datasheet.
- Click Send to Receiver.
- Choose All Receiving Cards for a first-time build. Use Specify Receiving Card only when replacing one card in a working wall.
- Confirm the success message, then Save.
If no RCFGX file exists, a working screen can still be rescued: Read Back pulls the parameters already stored on the receiving cards and lets you save them as a new file. This only works when the wall is already lighting up, even badly, because the card has to be reachable and powered.
How Do You Build the Screen Connection in NovaLCT Screen Configuration?
The third tab, Screen Connection, is where the physical layout becomes a map. It is built from four inputs, in this order:
- Number of screens — one for a single wall; several if the controller drives separate displays.
- Columns and rows of cabinets — the grid shape, again counted in cabinets.
- Sending card and output port — which port feeds the cabinets you are about to place.
- Receiving card size — the cabinet pixel width and height, taken from the previous tab.
After that, either draw the daisy chain cabinet by cabinet, or use Quick Connection, which fills standard rectangular layouts with a preset routing pattern. Irregular walls, mixed cabinet sizes and L-shaped screens still need the chain drawn manually, and NovaLCT will only accept a route that starts from the port and ends without a break.

Press Send to HW when the map looks right. The sending card stores it; the PC copy is only a working file. Then use Save to File to write the .scr connection file, which is what you reload if the controller is replaced.
How Do You Verify a NovaLCT Screen Configuration Before Handover?
A configured wall is not a verified wall. Verification is a separate pass, and it is the part that separates a screen that works on the day of installation from one that stays working after the first service call.
- Enable Mapping overlays the cabinet number and position on each cabinet. Every number should appear in the right physical location, with no duplicates and no gaps.
- Detect Communication Status lists which receiving cards answer and on which port. A card that is silent here has a cable or power fault, not a software fault.
- A full-screen test pattern at native resolution reveals scaling, cropping and single-port failures that a normal image can hide.
- Read back the configuration after sending, and compare it with what you intended to send.
Excel LED Display records four things at that point and ships them with the screen: the winning RCFGX file, the .scr connection file, the NovaLCT version used, and a photo of the mapping screen with cabinet numbers visible. An installer receiving the wall can load the two files, run Enable Mapping, and see the same numbers on the same cabinets — which turns commissioning into a check rather than a reconfiguration.
Which Files Should You Save After NovaLCT Screen Configuration?
Three file types carry the whole configuration, and a fourth now comes from the cloud. Keep all of them together with the project name and the date.
| File | What it holds | When you need it |
|---|---|---|
| .rcfgx | Receiving card parameters for one cabinet build | Replacing a receiving card or adding cabinets |
| .scr | The cabinet-to-port connection map | Replacing a sending card or rebuilding a wall |
| .cfg | NovaLCT version and the receiving card program package | Matching firmware after a controller swap |
| NCP | Cloud package, retrievable by file ID or order number | Re-downloading a configuration with no local backup |
The NCP route is the V5.9.2 addition at the time of writing: Load from Cloud searches a package by file ID or order number instead of browsing a local folder. It is a convenience for service teams, not a replacement for keeping your own copy — a cloud lookup is only useful while the screen’s record still exists in the account that configured it. When those files are about to be replaced rather than created — a controller swap or a firmware change — the backup and recovery sequence is covered in our NovaStar firmware update guide.
What Are the Most Common NovaLCT Configuration Mistakes?
- Entering module counts where cabinet counts belong. A 640 × 480 cabinet built from four 320 × 240 modules is one cabinet, not four. Entering module counts doubles both axes and halves the image.
- Saving the receiving card parameters without sending them. The Save button writes to the PC. Send to Receiver writes to the cards, and only the second one changes the wall.
- Building the connection map and skipping Send to HW. The map exists in software until it is pushed to the sending card.
- Mixing cabinet builds on one port. Cabinets with different pixel sizes or driver ICs need their own RCFGX and often their own port, even when the physical wall is continuous.
- Leaving Windows scaling at 125% or 150%. The sending card then receives a smaller logical image than the wall can show, and the content is stretched to fill it.
References & Sourced From: NovaLCT Screen Configuration Coverage
- NovaStar, NovaLCT — LED Configuration Tool for Synchronous Control System User Manual, V5.3.1. Screen Configuration, Receiving Card and Screen Connection chapters.
- NovaStar NCE training, NovaLCT Basic Configuration (26 min), official NovaStar channel, 2020.
- NovaStar NCE training, 2. Basic Configuration of NovaLCT (2022), official NovaStar channel — cabinet resolution and per-port loading chapters.
- NovaStar, NovaLCT V5.9.2 Release Notes, current version at the time of writing.
Frequently Asked Questions About NovaLCT Screen Configuration
What is the default NovaLCT login password?
The default password for Advanced Synchronous System User Login is admin. Status views work without logging in; the deeper configuration pages do not.
Can NovaLCT screen configuration run without a sending card?
Only in the demo mode offered in the User menu, which lets you practise the interface with no hardware attached. A real configuration requires a powered sending card connected by USB or Ethernet.
Why do the sending card and graphics output resolutions differ?
Windows display scaling or a graphics driver setting is resampling the image. Set scaling to 100%, set the LED screen’s resolution to its native pixel size, and turn off GPU scaling, then press Refresh in NovaLCT.
Do NovaLCT rows and columns mean cabinets or modules?
Cabinets. One cabinet normally equals one receiving card. Entering modules gives a map several times larger than the physical wall.
What can I do if I have no RCFGX file for the receiving cards?
Use Read Back on the Receiving Card tab. It pulls the parameters already stored on a working receiving card and lets you save them as an RCFGX file for future service.
Does NovaLCT work on macOS?
No. NovaLCT is a Windows application for Windows 7 and later. Mac-based teams either run it in a Windows virtual machine or use SmartLCT for the tasks it supports.
Which NovaStar controller should carry a large wall?
Port count and per-port loading decide it. A single MCTRL300 suits a small wall, while larger or higher-resolution screens move to the MCTRL600, MCTRL660 or MCTRL660 PRO or to an all-in-one VX4S-N, VX600 or VX1000.
How Do You Start Your First NovaLCT Screen Configuration?
NovaLCT screen configuration comes down to four numbers and two sends. Get the graphics output right, match the sending card to it, load the cabinet parameters from the file your supplier provides, and draw the cabinet map onto the correct ports. Then send both halves to hardware and verify with Enable Mapping before anyone calls the screen finished.
If you are still choosing the hardware that will carry that configuration, the difference between a synchronous wall and a player-driven one decides the whole toolchain — our comparison of synchronous and asynchronous LED display control covers that fork. Receiving card choice matters just as much, because loading capacity sets how many cabinets a port can carry; the MRV vs DH vs AT receiving card comparison breaks that down by cabinet size. For a full hardware shortlist, the LED control system collection lists 74 controllers and cards, and player-based projects continue with the Taurus TB player comparison.
Excel LED Display pre-configures NovaLCT for every screen we build and ships the RCFGX and connection file with the cabinets, so on-site work starts from a verified map. For a controller and cabinet combination matched to your pixel budget, contact our engineers or open the inquiry form below.
Need a NovaStar-controlled LED display configured and ready to run?