Mean Well UHP-200-5 Power Supply
5V 40A · 200W rated · fanless slim 194 × 55 × 26mm · 91% efficient · active PFC · DC OK & redundant options

A 200W 5V supply in a 26mm-tall fanless case less than half the width of a standard enclosed unit — and the only one in this range whose datasheet requires you to mount it on an aluminium plate — supplied by Excelled Display, LED display manufacturer and component supplier for global B2B integrators.

Mean Well UHP-200-5 5V 40A fanless slim switching power supply with honeycomb perforated cover and terminal block

Mean Well UHP-200-5 Power Supply at a Glance

What is it? The UHP-200-5 is the 5V model in the MEAN WELL UHP-200 series of slim type enclosed power supplies with active PFC. It delivers a regulated 5V DC output at up to 40A from a fanless case measuring 194 × 55 × 26mm and weighing 0.468kg.

How much power does it deliver? 200W — exactly what the name says. 5V × 40A = 200W. In a range where model numbers routinely overstate the 5V output — the LRS-350-5 gives 300W, the RSP-500-5 gives 450W — this one is honest at 5V.

How efficient is it? 91% typical at 5V. That is the highest efficiency of any 5V supply in this comparison set, and it is why a fanless 26mm case can handle 200W where a bigger fanless unit needs more room. At 91%, delivering 200W means roughly 20W of waste heat — against roughly 30W for an 87%-efficient supply of the same output.

Is there a catch to the fanless design? Yes, and it is on the datasheet rather than in the marketing: the UHP-200 series must be installed onto an aluminium plate, or onto a cabinet of the same size, on the bottom. The datasheet’s installation section specifies a suggested plate of 300 × 300mm with an even, smooth surface (or thermal grease applied), with the unit firmly mounted at the centre of the plate. The derating curves are drawn on that basis. Full details below — it is the single most important installation fact about this supply.

What does it take in? A 90–264VAC input, or 127–370VDC, at 47–63Hz, with cold-start inrush current limiting. Full-range input means no 115/230V selector switch. Note the low line is 90VAC, narrower than the 85–88VAC of the RSP models.

What optional functions does it offer? Two, and neither appears on the RSP 5V models: a DC OK signal reporting output status to a monitoring circuit (contact rating 15Vdc / 10mA resistive load), and a redundant function on the UHP-200R variant, which allows two units to be connected in parallel so that if one fails the other is automatically enabled.

What is it used for? LED display modules and cabinets where vertical space is at a premium, factory control and automation apparatus, test and measurement instruments, laser-related machinery, burn-in facilities and RF applications. Configuration, MOQ and pricing from our sales team.

Mean Well UHP-200 5V power supply honeycomb perforated cover angled view showing fanless cooling surface and terminal block
Mean Well UHP-200 power supply top view showing full honeycomb perforation pattern and 194 by 55mm slim footprint
Series Decoding

The UHP-200 Series: Nine Voltages and the One That Lands Exactly on 200W

The UHP-200 series covers nine voltages from 3.3V to 55V. The three lowest share a 40A current ceiling, and only the 5V model converts that ceiling into exactly the 200W the series is named for.

Model Output voltage Rated current Rated power Efficiency (typ.)
UHP-200-3.3 3.3V 40A 132W 89%
UHP-200-4.2 4.2V 40A 168W 90%
UHP-200-5 5V 40A 200W 91%
UHP-200-12 12V 16.7A 200.4W 93%
UHP-200-15 15V 13.4A 201W 94%
UHP-200-24 24V 8.4A 201.6W 94%
UHP-200-36 36V 5.6A 201.6W 94%
UHP-200-48 48V 4.2A 201.6W 94%
UHP-200-55 55V 3.6A 201.6W 94%
The 5V model is the efficient end of its own group. Across the 40A trio the efficiency climbs with voltage: 89% at 3.3V, 90% at 4.2V, 91% at 5V. The 5V model is the only one of the three that reaches the series’ advertised wattage, and it does so at the best efficiency in that group. If a cabinet is being specified around a 3.3V or 4.2V rail instead, note that the same case, the same 40A and the same price band buy only 132W or 168W.

One specification is worse at 5V than at the lower voltages: ripple and noise. The 3.3V and 4.2V models are quoted at 150mVp-p, while the 5V model is 200mVp-p. Higher ripple is normal as current rises at low voltage, but on a 5V rail it is worth knowing before a screen shows noise-related artefacts that are blamed on the modules.

Specifications

UHP-200-5 Specifications: Datasheet Parameters for the 5V 40A Model

Transcribed from the MEAN WELL UHP-200 specification sheet (UHP-200-SPEC, revision dated 2020-09-29) for the 5V model. Unless stated otherwise, readings are taken at 230VAC input, rated load and 25°C ambient.

Parameter UHP-200-5 specification
DC output voltage 5V, adjustable 4.5 ∼ 5.5V via SVR
Rated current 40A
Rated power 200W
Ripple & noise (max.) 200mVp-p at 20MHz bandwidth (150mVp-p on the 3.3V and 4.2V models)
Voltage tolerance ±2.0% (includes set-up tolerance, line regulation and load regulation)
Line regulation ±0.5%
Load regulation ±1.0% from 0% to 100% rated load
Set-up / rise time 2000ms, 80ms/230VAC; 3000ms, 80ms/115VAC at full load
Hold-up time (typ.) 10ms at 230VAC and 10ms at 115VAC, full load
Input voltage range 90 ∼ 264VAC, no selector switch; 127 ∼ 370VDC
Input frequency 47 ∼ 63Hz
Power factor (typ.) PF > 0.94 / 230VAC, PF > 0.98 / 115VAC at full load
Efficiency (typ.) 91% at 5V; the series spans 89% at 3.3V to 94% at 15V and above
AC current (typ.) 2.2A/115VAC, 1.1A/230VAC
Inrush current (typ.) Cold start 40A/115VAC, 80A/230VAC
Leakage current <0.75mA / 240VAC — the lowest of the supplies on this page’s comparison set
Overload protection 110 ∼ 140% rated output power; hiccup mode, recovers automatically once the fault is removed
Over-voltage protection 5.75 ∼ 6.75V; shuts down the output, re-power required to recover
Over-temperature protection Shuts down output or enters hiccup mode, recovers automatically once temperature falls
Cooling Fanless — free air convection. Requires an aluminium mounting plate; see the installation section
DC OK signal Optional. Collector-shorted signal via optocoupler; contact rating max. 15Vdc / 10mA resistive load
Redundant function Optional (UHP-200R). Two units may be connected in parallel; if one fails the other is automatically enabled
Working temperature −30 ∼ +70°C with derating (refer to the derating curves)
Working humidity 20 ∼ 95% RH non-condensing — a wider range than the 20∼90% RH of the RSP series
Storage −40 ∼ +85°C, 10 ∼ 95% RH non-condensing
Temperature coefficient ±0.03%/°C (0 ∼ 50°C)
Vibration 10 ∼ 500Hz, 5G, 10 min per cycle, 60 min each along X, Y and Z axes
Withstand voltage I/P–O/P 3.75KVAC; I/P–FG 2KVAC; O/P–FG 1.25KVAC
Isolation resistance I/P–O/P, I/P–FG, O/P–FG: 100MΩ / 500VDC at 25°C, 70% RH
Dimensions (L×W×H) 194 × 55 × 26mm (Case No. 249B)
Weight / packing 0.468kg per unit; 24pcs / 12.2kg / 0.49CUFT per carton
MTBF 257K hours min. (MIL-HDBK-217F at 25°C). No Telcordia figure is quoted on this revision
Warranty 3 years (manufacturer’s stated warranty on the datasheet)

Two figures stand out against everything else in this comparison set: the 5G vibration rating, against 2G on the RSP models, and the 1.25KVAC output-to-frame withstand, against 0.5KVAC on the RSP models. Both suggest a unit built for a more demanding mechanical and isolation environment than the standard enclosed range.

Installation

The UHP-200-5 Aluminium Plate Requirement: Mount It or Lose the Rating

This is the most consequential thing on the UHP-200 datasheet, and it is the one detail that reseller listings routinely omit. The installation section states that in order to meet the derating curve and the static characteristics, the UHP-200 series must be installed onto an aluminium plate — or onto the cabinet of the same size — on the bottom of the unit.

Requirement What the datasheet specifies
Mounting surface An aluminium plate, or a cabinet acting as the same, on the bottom of the unit
Suggested plate size 300 × 300mm
Surface condition Must be even and smooth; or coated with thermal grease
Mounting position The unit must be firmly mounted at the centre of the plate
Why it is required The derating curve and static characteristics are defined on this basis — without it the published ratings do not apply

What happens if you ignore it

  • The unit still works — it just no longer meets its published rating. This is why the omission is dangerous rather than obvious. A UHP-200-5 screwed to a thin painted panel will run, pass a bench test, and fail in service when the cabinet gets hot.
  • There is a separate derating curve for operation without the aluminium plate. The datasheet draws one set of curves against ambient temperature and another explicitly labelled ambient temperature without aluminium plate. The second set is lower. That gap is the practical cost of skipping the plate.
  • There is also a curve against case temperature (Tcase). MEAN WELL provides three ways to read the thermal limit — ambient with plate, ambient without plate, and case temperature — so a design can be validated whichever measurement is practical on site.
  • The plate is not a mounting bracket. It is a heatsink. A painted, uneven or undersized panel has thermal resistance of its own, which is why the datasheet specifies bare aluminium, a smooth surface, and thermal grease as an alternative to a perfect finish.
On a screen, this usually means the cabinet frame is the plate. An LED display cabinet’s metal structure can serve as the required surface if it is genuinely flat, unpainted where it contacts the unit, and large enough to spread the heat. That has to be an intentional decision in the cabinet design rather than an assumption made at installation. If the cabinet structure cannot serve, a 300 × 300mm aluminium plate has to be added — and on a slim supply chosen precisely because space was tight, that is a real constraint. Raise it at specification stage.

Mean Well UHP-200 fanless power supply side profile showing 26mm slim case height vent slots and mounting flange

Format

UHP-200-5 Slim Fanless Format: 194 × 55 × 26mm and 0.468kg

The reason to choose this supply over the RSP-200-5 is physical before it is electrical. At the same 200W and the same 40A, the UHP-200-5 occupies roughly half the footprint width and a lower profile, and weighs about 35% less.

Dimension UHP-200-5 RSP-200-5
Length 194mm 215mm
Width 55mm 115mm
Height 26mm 30mm
Weight 0.468kg 0.72kg
Units per carton 24pcs / 12.2kg 15pcs / 11.8kg
Cooling Fanless, honeycomb perforated case Fanless, perforated case
Cooling surface requirement Aluminium plate required Free air convection

Where the slim format earns its place

  • Narrow cabinet sections. At 55mm wide against 115mm, two UHP units fit in the width one RSP occupies — which is how a slim supply changes a cabinet layout rather than just fitting into it.
  • Shallow cabinets and rear-service voids. 26mm against 30mm is a small difference on its own, but on a supply that must also sit against a plate, every millimetre of stack height counts.
  • Shipping and handling. 24 units per 12.2kg carton against 15 per 11.8kg. On a multi-cabinet project that is a meaningful difference in freight volume and in how the units are handled on site.
  • But the plate requirement follows the slim format. Removing the fan and shrinking the case is exactly why the mounting surface has to carry heat away. The slimness and the plate requirement are the same design decision seen from two sides.

Mean Well UHP-200 power supply internal view with cover removed showing PCB capacitors and transformer layout for fanless heat path

MEAN WELL also supplies the same 200W slim format in a variant carrying the redundant function and an optional DC OK signal — covered next.

Optional Functions

UHP-200-5 DC OK Signal and the UHP-200R Redundant Function

The UHP-200 series offers two optional functions that the RSP 5V models do not have at all. They matter for screens that must report their own health or keep running when a supply fails.

DC OK signal — output status to a monitoring circuit

DC OK is a collector-shorted signal produced by an optocoupler inside the supply, indicating output status. When the unit turns on, the optocoupler’s collector-emitter pin conducts; when the output fails, the pin goes open. The contact rating is 15Vdc / 10mA resistive load, and it is brought out on connector CN10 (JST B2B-PH-K-S or equivalent, pin 1 DC COM, pin 2 DC OK +V).

  • What it gives you: a per-supply status line that a monitoring board or control system can read — so a failed supply is identified rather than inferred from a dark section of screen.
  • What it is not: it is not a current or voltage measurement, and it is not a fault code. It reports on or off, nothing finer.
  • The contact rating is small. 10mA at 15Vdc is a logic-level signal. Do not switch a relay coil or an indicator lamp directly from it without checking the load.

Redundant function — the UHP-200R parallel variant

The UHP-200R has a built-in redundant function and can be connected two units in parallel. The datasheet describes the behaviour precisely: for parallel applications, when one power supply cannot work, the other is automatically enabled, preventing a system crash and improving system reliability.

The parallel rule is the important part. The datasheet states that when in parallel operation, the maximum load should not be greater than the rated power of any one power supply. This is not load-sharing for capacity — it is redundancy for availability. Two UHP-200R units in parallel do not give you 400W; they give you 200W with a spare. Sizing a cabinet as though the pair delivers 400W and then discovering this rule is an expensive mistake, and it is stated on the datasheet rather than buried in a note.

Neither function is a substitute for planning capacity. If a section genuinely needs more than 200W at 5V, split it into independently supplied sections or move to a higher-current model — the UHP-350-5 power supply or the RSP-500-5 — rather than paralleling units for wattage.

Comparison

UHP-200-5 vs RSP-200-5: Same 200W, Different Engineering

These two are the closest comparison in the whole MEAN WELL 5V range: both fanless, both 200W, both 40A at 5V. The differences are in efficiency, format, mounting and the environment each is built for.

Parameter UHP-200-5 RSP-200-5
Output 5V / 40A 5V / 40A
Rated power 200W 200W
Type Slim type with PFC Enclosed with PFC
Efficiency (typ.) 91% 87%
Cooling Fanless Fanless
Mounting surface Aluminium plate required Free air convection
Dimensions 194×55×26mm 215×115×30mm
Weight 0.468kg 0.72kg
Input range 90∼264VAC 88∼264VAC
Power factor PF > 0.94 PF > 0.95
Leakage current <0.75mA <1mA
Overload range 110∼140% 105∼135%
Hold-up time 10ms 8ms
Vibration 5G 2G
O/P–FG withstand 1.25KVAC 0.5KVAC
EMC immunity level Heavy industry Light industry
DC OK / redundant options Yes Not offered
Conformal coating option Not offered Yes, -CC suffix

How to choose between them in one line each

  • Choose the UHP-200-5 when space or weight is the constraint, when higher efficiency matters for a sealed or densely packed cabinet, when the installation is subject to vibration, or when the screen needs to report supply status or run with a redundant spare.
  • Choose the RSP-200-5 when the mounting surface cannot be guaranteed flat, unpainted and large enough to act as a heatsink; when the installation is humid or coastal and the conformal coating option is the mitigation you want; or when a marginally lower low-line input limit matters.
  • Do not choose on wattage. They are identical at 200W and 40A. Every other line in that table is the actual decision.
The plate requirement is the deciding factor more often than the numbers. On paper the UHP-200-5 wins on efficiency, size, weight, vibration and isolation. In practice, a cabinet whose structure cannot serve as the required aluminium surface makes the RSP-200-5 the simpler and more honest choice — because the RSP’s rating does not depend on a mounting condition that the installation may not satisfy.
Sizing

How Many LED Modules Can One UHP-200-5 Power?

No supplier can answer this without knowing your module. The count depends on the maximum power rating of your LED module from its own datasheet, the number of modules on the supply, and the thermal headroom you leave — which on this supply depends on the mounting surface as much as the load.

  1. Start from the real rating. 200W at 5V, which is 40A.
  2. Apply a load ceiling. A common planning rule in LED cabinet builds is to keep continuous load at or below about 80% of rated output — roughly 160W, or 32A, on a UHP-200-5. This is an engineering convention rather than a MEAN WELL figure; confirm it against your own project’s thermal and warranty conditions.
  3. Divide by the module’s maximum power, taken from the module datasheet rather than a marketing page — full white is the condition a screen is commissioned under.
  4. Confirm the mounting surface. Read the derating curve that matches the installation: with the aluminium plate, or without it. The answer changes the usable load.
  5. Check the current path. 32A still has to leave through the terminal block and reach the modules. Confirm wire gauge, terminal rating and the number of feeds.
  6. Check the capacitance on the 5V rail. If the cabinet carries a large capacitor bank, raise it at quotation so the start-up behaviour can be confirmed.

Worked as an Illustrative Example — substitute your own module figures; these numbers are for the arithmetic only:

Step Illustrative calculation
Supply rating 200W / 40A at 5V
Usable at 80% planning ceiling 160W / 32A
Module maximum power (illustrative) 25W per module
Modules per supply (160 ÷ 25) 6 modules, with 10W of the usable budget unspent
Heat into the cabinet at that load ≈16W at 91% efficiency — roughly half that of an equivalent 87%-efficient supply at the same output

For the control and signal side of the same cabinet, the LED control system collection covers how sending cards, receiving cards and processors are powered and wired alongside the supplies.

Wiring

UHP-200-5 Wiring: TB1 AC Input, Twin DC Output Blocks and CN10

The UHP-200-5 uses a different terminal arrangement from the RSP models: one AC input block, two separate DC output blocks, and a signal connector for the optional DC OK function.

Block Pin Assignment Practical note
TB1 — AC input 1 AC/L — live Mains live input
2 AC/N — neutral Mains neutral input
3 Frame ground (FG) Bond to the cabinet earth; do not omit
TB2 / TB3 — DC output 1, 2 DC OUTPUT −V Two terminals, shared negative rail
3, 4 DC OUTPUT +V Two terminals, shared positive rail
CN10 — DC OK 1 DC COM Optocoupler return
2 DC OK +V Optocoupler collector; 15Vdc / 10mA max

Terminal hardware, as specified on the datasheet: the AC input block is a DEGSON DG28C-B-03P with a maximum mounting torque of 5kgf-cm; the DC output terminals are TB-HTP-200-40A with a maximum torque of 8kgf-cm. The DC OK connector is a JST B2B-PH-K-S or equivalent, mating with a JST PHR-2 housing and SPH-002T-P0.5S terminals. Tightening beyond the stated torque damages the block, and on a 40A output a loose terminal is a heat source.

One detail in the copy of the datasheet we hold: the third AC terminal’s label does not render legibly in our extract, though the block is a three-pin AC input with live and neutral at pins 1 and 2. Confirm the third terminal against the marking printed on the unit itself before wiring.

Mean Well UHP-200 power supply model label and terminal block detail showing MEAN WELL marking certification icons and output terminals

There is no input voltage switch to set

The UHP-200-5 is full-range 90–264VAC with no selector switch. Nothing to select and nothing to get wrong, and one part number covers both 120V and 230V sites. Note that the low line is 90VAC rather than the 85–88VAC of the RSP models — on a site with a persistently low supply, that difference is worth checking against the static characteristic curve.

Split the load across both output blocks

At 40A, use both +V and both −V terminals and keep the DC run to the first module as short as the cabinet allows. At this current, terminal contact resistance and local heating are the practical limits rather than the supply’s own regulation.

Mount it on the plate before anything else

Sequence matters on this supply. The aluminium plate or equivalent cabinet surface has to be in place before the unit is commissioned, because the rating depends on it. Mount at the centre of the plate, on a smooth even surface, with thermal grease if the finish is not bare and flat. Then leave the honeycomb perforated face clear so convection can move air across the case.

The same wiring discipline applies to the control hardware inside the cabinet. Our guides to the MCTRL660 LED display controller and the Colorlight X2 LED video processor cover the signal side, and the Huidu HD-A5 LED display player covers standalone playback for screens that run without a PC.

Compliance

UHP-200-5 Certifications: Heavy Industry Immunity and 3.75KVAC Withstand

The UHP-200-5 carries a different and in some respects stronger compliance profile than the RSP 5V models, including an appliance-safety standard and a heavier immunity classification.

Item Detail from the UHP-200 datasheet (revision dated 2020-09-29)
Safety standards UL 62368-1, TUV EN62368-1, EN60335-1 (except for 55V), CCC GB4943, EAC TP TC 004, BSMI CNS14336-1 approved; design refers to EN61558-1, -2-16
Withstand voltage I/P–O/P 3.75KVAC; I/P–FG 2KVAC; O/P–FG 1.25KVAC
EMC emission Compliance to EN55032, GB9254, Class B, EN55014, EN61000-3-2, -3, EAC TP TC 020, BSMI CNS13438
EMC immunity Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020
Isolation resistance 100MΩ / 500VDC at 25°C, 70% RH
MTBF 257K hrs min. MIL-HDBK-217F at 25°C

Heavy industry immunity is a real difference

The RSP models are tested to light industry level. The UHP-200 is tested to heavy industry level with criteria A under EN61000-6-2. Criteria A means the equipment continues to operate as intended with no degradation during the disturbance — not merely that it survives. On a screen sharing a supply with welders, motors or switched inductive loads, that classification is the specification that predicts whether the image stays clean.

EN60335-1 and the EN61558 design reference

Two entries deserve reading carefully rather than skimming. EN60335-1 is the household and similar electrical appliance safety standard, and it applies to every model in this series except the 55V variant. Separately, the EN61558-1 and -2-16 reference is stated as a design reference rather than an approval — which is a different level of claim from the RSP-320 datasheet, where EN61558-1/2-16 is listed as an approval for 12V-or-higher models. If a tender names EN61558 as an approval requirement, the distinction between “approved to” and “design refers to” has to be clarified with the manufacturer before the specification is fixed.

Component, not appliance. MEAN WELL specifies this unit as a component to be installed into final equipment and states the final equipment must be re-confirmed as still meeting the EMC directives. An UHP-200-5 on a bench is a certified component; inside a screen it is part of a system whose EMC must be validated in its own right. We work from the revision we hold — for this model, 2020-09-29 — and say so rather than implying a certification we have not seen. On EU-bound projects, tell us the destination country and the total cabinet input power and we will confirm which family meets the harmonic and EMC requirements at quotation stage.
Fit

When the UHP-200-5 Is the Wrong Power Supply

A page that cannot tell you when not to buy something is a catalogue entry, not advice. The UHP-200-5 is the right answer for 200W of 5V in a space-constrained, vibration-exposed or monitoring-critical installation, and clearly wrong in the following cases:

Situation Why the UHP-200-5 does not fit
No flat, unpainted aluminium surface available The rating depends on the mounting plate. If the cabinet cannot provide it, the RSP-200-5 gives the same 200W and 40A without that condition.
Humid, coastal or condensation-prone site The UHP-200 series does not list a conformal coating option. The RSP-200-5 does, as the -CC suffix.
5V load above 200W per supply section The 40A ceiling is the limit of this model. Step up to the UHP-350-5 power supply or the RSP-500-5, or split the cabinet into separately supplied sections.
Expecting 400W from two UHP-200R units in parallel The datasheet states that in parallel operation the maximum load must not exceed the rated power of any one supply. The pair gives 200W with a spare, not 400W.
Very low or unstable mains The low line is 90VAC against 85–88VAC on the RSP models. On a persistently low supply, check the static characteristic curve before specifying.
The screen must ride through a mains dip Hold-up is 10ms at full load. That requirement is solved with a UPS or DC-side hold-up, not by changing supply model.
A tender that requires EN61558 approval On this datasheet the EN61558-1/-2-16 reference is stated as a design reference, not an approval. Clarify with the manufacturer before fixing the specification.
Noise-sensitive modules on the 5V rail Ripple and noise is 200mVp-p at 5V, against 150mVp-p on the 3.3V and 4.2V models of the same series. If the module datasheet has a tight ripple tolerance, check it.
No PFC or harmonic requirement, and cost decides PFC is much of what you are paying for. An LRS-200-5 gives 200W of 5V for less money where nothing in the specification demands PFC.

Where the power supply is the wrong component to be choosing at all, the constraint is usually elsewhere in the system. On the indoor product side, pages such as the P3.91 rental LED display and the P2.5 indoor LED display set out the module-level specifications those decisions start from.

Troubleshooting

UHP-200-5 Troubleshooting: Thermal Derating, Hiccup Mode and DC OK

On this supply the most common field problem is not a fault at all — it is a rating that no longer applies because the mounting condition is wrong. Work through these in order.

The screen dims or the supply shuts down as the cabinet warms up

  • Possible cause: insufficient heatsinking. Either no aluminium plate, an undersized one, a painted or uneven surface, or the unit mounted off-centre rather than at the centre of the plate.
  • How to check: measure case temperature and cabinet ambient, and compare against the derating curve for the actual mounting condition. The datasheet provides a separate curve for operation without the aluminium plate — read that one if no plate is fitted.
  • Fix: fit the plate, or fit a larger one, mount at the centre, and use thermal grease if the surface is not bare and smooth. This is the first thing to check on this model before suspecting the supply itself.

Output drops out and recovers on its own, repeatedly

  • Possible cause: overload hiccup mode at 110–140% of rated power, or over-temperature protection — which on this model may either shut the output down or enter hiccup mode. Both recover automatically, so both look identical from outside.
  • How to check: measure DC current at full white, then case temperature and ambient. A clamp meter and a thermometer usually separate the two.
  • Fix: if current exceeds the planning ceiling, split the load. If the unit is hot, fix the mounting and airflow — this supply has no fan to mask a marginal thermal design.

No output at all, and it stays off after a power cycle

  • Possible cause: over-voltage protection has latched. OVP trips between 5.75V and 6.75V, shuts the output down and requires a re-power to recover — unlike overload and over-temperature, which both self-recover.
  • How to check: remove the load and re-power. If the output returns with no load connected, the trip was load-related rather than a supply failure.
  • Fix: correct what drove the output above the OVP threshold — typically a load fault or a wiring error — before reconnecting.

The DC OK signal reads “fail” while the screen appears to work

  • Possible cause: the monitoring circuit is miswired or the optocoupler load exceeds its rating. DC OK switches a collector-emitter output rated at 15Vdc / 10mA resistive load, and it is a status signal rather than a measurement.
  • How to check: verify the wiring on CN10 (pin 1 DC COM, pin 2 DC OK +V) and confirm the external load is within the contact rating.
  • Fix: drive the monitoring input directly or through an appropriate interface, not a relay coil or lamp. If the signal says fail and the output is genuinely present, the sense circuit is the fault, not the supply.

The screen takes two to three seconds to come on after mains is applied

  • Possible cause: nothing is faulty. Set-up is 2000ms at 230VAC and 3000ms at 115VAC, with an 80ms rise time.
  • How to check: measure the delay from mains applied to output stable and compare with the datasheet figure for the site voltage.
  • Fix: no fix required if the delay matches specification. If control logic assumes supplies are ready sooner, adjust sequence timing rather than replacing hardware.

Screen brightness drops or pixels discolour at the far end of a run

  • Possible cause: voltage drop along the DC path, not a supply fault. At 5V, cable resistance takes a proportionally large bite out of the delivered voltage.
  • How to check: measure voltage at the supply terminals and again at the input of the last module on the run. The difference is the drop.
  • Fix: shorten the run, increase the conductor cross-section, or split the feed. Then trim the SVR adjustment so the module input reads its specified 5V under load — not so the supply terminal reads 5V. Unlike the RSP-500-5, this model has no remote sense to correct the drop for you.
Downloads

UHP-200-5 Datasheet and Series Documentation

The documents below are the manufacturer’s own files, hosted by MEAN WELL. They are the reference we work from, and the correct place to verify any specification quoted on this page — including the aluminium plate installation requirement and the derating curves.

Document What it covers
UHP-200 series datasheet (PDF) Full specification table for all nine voltage models, the three derating curves, static characteristics, block diagram, mechanical drawing, terminal assignment and the installation section covering the aluminium plate
UHP-200 series product page All voltage variants with their individual model datasheets, certificates and the DC OK and redundant function options
Installation manual Manufacturer installation guidance for the UHP slim series

Mean Well UHP-200 power supply mechanical drawing showing 194 by 55 by 26mm dimensions mounting holes and terminal block positions

MEAN WELL prints a serial number on each unit that can be traced on the manufacturer’s own website. That is the authoritative way to confirm a batch’s provenance and production date — more reliable than any listing photograph, including ours.

FAQ

Mean Well UHP-200-5: Frequently Asked Questions

QHow many watts is the Mean Well UHP-200-5?

200W. At 5V and 40A the output is exactly 200W, so the series name matches the actual 5V rating on this model. The 3.3V and 4.2V models in the same series deliver only 132W and 168W from the same 40A ceiling.

QDoes the UHP-200-5 need to be mounted on an aluminium plate?

Yes. The datasheet installation section states that to meet the derating curve and static characteristics, the UHP-200 series must be installed onto an aluminium plate, or a cabinet of the same size, on the bottom. The suggested plate is 300 by 300mm with an even smooth surface, and the unit must be mounted at the plate’s centre. A separate lower derating curve applies without the plate.

QDoes the UHP-200-5 have a fan?

No. It is cooled by free air convection through a honeycomb perforated case, with no fan and no moving parts. The trade-off is the mounting plate requirement: because there is no fan, the mounting surface has to carry the heat away.

QWhat is the efficiency of the UHP-200-5?

91% typical at the 5V output, measured at 230VAC input and rated load. That is the highest of the 40A group in this series, which runs 89% at 3.3V and 90% at 4.2V, and it is higher than the 87% of the equivalent RSP-200-5.

QWhat is the difference between the UHP-200-5 and the RSP-200-5?

Format, efficiency and mounting. Both deliver 200W at 5V and 40A and both are fanless, but the UHP-200-5 is a slim type measuring 194 by 55 by 26mm at 0.468kg with 91% efficiency, while the RSP-200-5 is 215 by 115 by 30mm at 0.72kg with 87%. The UHP also requires an aluminium mounting plate and offers DC OK and redundant options; the RSP does not require a plate and offers conformal coating instead.

QCan two UHP-200R units be paralleled to get 400W?

No. The UHP-200R has a built-in redundant function allowing two units in parallel, but the datasheet states that in parallel operation the maximum load must not exceed the rated power of any one supply. Two units give 200W with a spare for redundancy, not 400W of capacity.

QWhat is the DC OK signal on the UHP-200?

DC OK is an optional collector-shorted signal produced by an optocoupler inside the supply that indicates output status. The collector-emitter pin conducts when the supply is on and goes open when it fails. The contact rating is 15Vdc at 10mA resistive load, and it is brought out on connector CN10.

QDoes the UHP-200-5 need a 115V or 230V selector switch set?

No. It accepts a 90 to 264VAC input with no selector switch, and also accepts 127 to 370VDC. Note the low line is 90VAC, which is narrower than the 85 to 88VAC range of the RSP models, so on a persistently low supply check the static characteristic curve.

QHow do I wire the UHP-200-5?

TB1 is the AC input with live at pin 1 and neutral at pin 2. TB2 and TB3 are the DC output blocks: pins 1 and 2 are DC negative and pins 3 and 4 are DC positive. CN10 carries the optional DC OK signal on pin 1 (DC COM) and pin 2 (DC OK +V). The output is adjustable between 4.5V and 5.5V using the SVR control.

QWhat is the overload protection behaviour of the UHP-200-5?

Hiccup mode at 110 to 140% of rated output power, recovering automatically once the fault is removed. The 110 to 140% band is wider than the 105 to 135% range of the RSP models. Over-voltage protection is the exception: it shuts the output down and requires a re-power to recover.

QWhat is the hold-up time of the UHP-200-5?

A typical 10 milliseconds at full load on both 230VAC and 115VAC. At 50Hz that is half a mains cycle, so the supply rides through small notches and transients but not a brownout, a source transfer or a generator changeover.

QWhat is the vibration rating of the UHP-200-5?

10 to 500Hz at 5G, for 10 minutes per cycle and 60 minutes each along the X, Y and Z axes. That is 2.5 times the 2G rating of the RSP series, and it is matched by a 1.25KVAC output-to-frame withstand voltage against 0.5KVAC on the RSP models.

Get UHP-200-5 Pricing for Your LED Display Project

Tell us your module voltage, the 5V load per cabinet, the available cabinet width and depth, and what the supply will be mounted against — because on this model the mounting surface is part of the specification. We will confirm whether the cabinet structure can serve as the required aluminium plate or whether a plate has to be added, whether you need the DC OK signal or the redundant UHP-200R variant, the quantity per screen and the delivered price.

Excelled Display supplies MEAN WELL power supplies alongside the modules, cabinets and control hardware they run with, so the thermal path, the mounting condition and the screen specification are confirmed together rather than in isolation. For the rest of the chain, see the LED control system collection, the outdoor LED display range and the LED display manufacturing process behind them.

Related reading: Mean Well RSP-200-5 power supply · Mean Well UHP-350-5 power supply · Mean Well UHP-500-5 power supply · Mean Well LRS-200-5 power supply · MCTRL660 LED display controller