Indoor modular LED display · 5 cabinet platforms · P0.625–P3.91 mm
Indoor Modular LED Display for Custom-Size Video Walls
An indoor modular LED display is a direct-view video wall assembled from standard LED modules and cabinets, so the finished screen follows the room instead of a fixed panel size. Excel LED manufactures five cabinet platforms, from a 1000 × 250 mm strip to a 600 × 337.5 mm 16:9 cabinet, and configures the modules, power, receiving cards and control as one package. This page explains how the system is built, how to calculate a custom size, which platform fits your room, and what a configuration costs in 2026.
01 · Definition
What Is an Indoor Modular LED Display and How Is It Built?
An indoor modular LED display is a direct-view video wall built from interchangeable LED modules mounted in standard cabinets. The module is the smallest replaceable pixel block; the cabinet is the structural and service unit; the cabinet grid defines the final width, height and aspect ratio. Because the wall is assembled rather than ordered as one sealed panel, a project can be sized to the opening, extended later and repaired one module at a time.
The word modular describes the mechanical system, not a picture-quality grade. A P1.25 modular wall and a P1.25 fixed-size wall can use the same pitch and the same LED lamps. What changes is how the wall is divided, transported, installed and serviced. Buyers should compare the module format, cabinet format, service direction and control capacity, rather than the pitch alone.
Three phrases appear in project briefs and searches: a modular indoor LED video wall is the finished assembly, indoor LED display modules are the replaceable pixel blocks, and modular LED screen panels usually means the cabinets. They describe the same stack at different levels. When a specification uses one term without the other two, ask which unit is being quoted.
The module sets the repair unit
The cabinet sets the structural grid
The control system sets the pixel budget
The wall is the geometry decision
For a supplier-neutral explanation of the full system stack, including modules, cabinets, power supplies, receiving cards and sending cards, read the modular LED display system guide. This page stays on the indoor product, the cabinet platform and the size calculation, so the two pages answer different questions.
02 · Architecture
How Do LED Modules, Cabinets and Control Fit Together in an Indoor Modular LED Display?
Four layers make the system, and each one fixes a different decision. The table below is the quickest way to see where a specification can go wrong: a project can have the right pitch and the wrong cabinet, or the right cabinet and a controller that cannot drive the pixel count.
| Layer | What it fixes | Excel LED example |
|---|---|---|
| LED module | Pixel block, repair granularity, spare-part size | 250 × 250 mm on PS; 320 × 160 mm on Ehonor and CPS; 150 × 168.75 mm on fine-pitch Cni and Uni builds |
| Cabinet | Wall geometry, structural depth, service direction | 1000 × 250 mm, 750 × 250 mm and 500 × 250 mm on PS; 640 × 480 mm on CPS; 600 × 337.5 mm on Cni and Uni; 480 × 320 mm on Ehonor; 320 × 480 mm on Ehonor Pro |
| Power and data | Reliability, heat and the per-cabinet pixel area | 5 V power supplies and NovaStar receiving cards inside the cabinet; confirm the exact model on the quotation |
| Control | Inputs, scaling, layers and total pixel capacity | NovaStar MCTRL or VX sending and processing, or Colorlight X series; capacity chosen from the wall resolution |
Each modular LED cabinet carries its own power supply and receiving card, so the cabinet is also the electrical unit. The pixel math is simple and worth doing before any quote is compared. A 320 × 160 mm module at P1.86 carries 172 × 86 pixels, because 320 ÷ 1.86 is 172 and 160 ÷ 1.86 is 86. A 640 × 480 mm CPS cabinet holds two modules across and three down, so the cabinet itself is 344 × 258 pixels. Multiply by the cabinet count and you have the native resolution of the wall.


Why the cabinet format matters more than the cabinet colour
Three cabinet decisions affect the project more than any finish option. The first is depth: the PS strip cabinet is 20.6 mm deep, which lets it sit in a shallow recess where a 70 mm Ehonor cabinet would not fit. The second is weight: a 1000 × 250 mm PS cabinet weighs 4.8 kg, the 750 mm version 3.6 kg and the 500 mm version 2.4 kg, and an Ehonor 480 × 320 mm cabinet weighs 3.0 kg. The third is flatness: the locking edges and the frame behind them decide whether the seams disappear at arm’s length.
A thin cabinet is not automatically the better choice. A shallow cabinet has less room for the power supply and the receiving card, and it may need a flatter wall behind it. A deeper cabinet is easier to service and often easier to set level on a steel frame. The right answer depends on the opening, the structure and the service direction, which is why the platform table below is organized by geometry rather than by price.
03 · Platforms
Which Indoor Modular LED Display Cabinet Platforms Does Excel LED Offer?
Excel LED builds five cabinet formats for indoor modular LED displays. They are not interchangeable price tiers; each one solves a different geometry or structure problem. A strip cabinet makes an ultra-wide wall or a shallow recess practical, a 16:9 cabinet makes a native 4K grid simple, and a lightweight 480 × 320 cabinet keeps a wall-mounted room within the structure’s budget.
| Platform | Module | Cabinet | Depth / weight | Pitch range | Best for |
|---|---|---|---|---|---|
| PS Series / PS Pro | 250 × 250 mm | 1000 × 250, 750 × 250, 500 × 250 mm | 20.6 mm; 2.4–4.8 kg | P1.56–P3.91 | Ultra-wide walls, shallow recesses, strip and ribbon screens |
| Ehonor | 320 × 160 mm | 480 × 320 mm | 70 mm; 3.0 kg | P1.25–P3.076 | Lightweight wall-mounted rooms, retail and conference |
| Ehonor Pro / Pro Max | 320 × 160 mm | 320 × 480 mm portrait | Confirm in quotation | P1.25–P3.076 | Portrait columns, narrow bays, SMD or COB builds |
| CPS / CPS Pro / Pro Max | 320 × 160 mm | 640 × 480 mm | Confirm in quotation | P1.2–P3 | 16:9 in a 4 × 3 cabinet grid; conference, control and retail |
| Cni / Uni | 150 × 168.75 mm fine pitch; 320 × 160 mm wider builds | 600 × 337.5 mm | 39.75 mm; 4 kg | P0.625–P1.875 | Native 4K and 8K grids, premium boardrooms and control rooms |
One dimensional note: some fine-pitch Cni and Uni builds use a 600 × 675 mm cabinet rather than the 16:9 600 × 337.5 mm format. The pixel math is the same, but the row count changes, so confirm the cabinet drawing for the exact pitch. The cabinet size is a mechanical decision; the pitch is an optical one. The same 600 × 337.5 mm cabinet can be built at P1.25 for a control room or at P1.875 for a larger room with a longer viewing distance. Decide the geometry first, then the pitch, then the packaging. Reversing that order is how projects end up with a screen that fits the budget but not the wall.

PS Series

Ehonor Series

CPS Series

Cni Series

Uni Series
Two related formats sit beside the five main platforms. The Ehonor Pro 320 × 480 mm portrait cabinet is useful for columns and narrow bays, while the Ehonor Pro Max COB version adds a sealed front for high-touch rooms. For a broader view of the indoor range, start at the indoor LED screen collection.
04 · Sizing
How Do You Size a Custom Indoor Modular LED Display and Calculate Resolution?
Start with the opening, not with a diagonal or a brochure size. The wall is a whole number of cabinets in both directions, so the first job is to find the cabinet grid that fills the opening with the smallest unused margin. Then choose the pitch that gives the resolution and viewing distance the room needs. This is the same calculation behind any custom-size indoor LED display quotation, whether the brief calls it a modular wall or a custom LED screen. The sequence is mechanical, and it prevents the two most common mistakes: a screen that misses the opening by 40 mm, and a 4K content plan that lands on a 2.5K wall.
The three numbers you need before asking for a quote
- Opening width and height in millimetres. Measure the finished opening, not the old screen. Note any skirting, door swing, ceiling bulkhead or service hatch that limits the frame.
- Closest viewer distance. The nearest seat, not the back of the room. Minimum comfortable distance is roughly the pitch in millimetres expressed in metres: P1.86 is about 1.9 m, P2.5 about 2.5 m.
- Content and target resolution. A native 1920 × 1080 wall, a 3840 × 2160 wall and an ultra-wide 32:9 wall lead to different cabinet counts even when the area is the same.
Resolution targets on a 600 × 337.5 mm cabinet
| Target resolution | P1.25 | P1.5625 | P1.875 | P2.5 |
|---|---|---|---|---|
| 1920 × 1080 | 4 × 4 cabinets 2.40 × 1.35 m |
5 × 5 cabinets 3.00 × 1.69 m |
6 × 6 cabinets 3.60 × 2.03 m |
8 × 8 cabinets 4.80 × 2.70 m |
| 3840 × 2160 | 8 × 8 cabinets 4.80 × 2.70 m |
10 × 10 cabinets 6.00 × 3.38 m |
12 × 12 cabinets 7.20 × 4.05 m |
16 × 16 cabinets 9.60 × 5.40 m |
| 7680 × 4320 | 16 × 16 cabinets 9.60 × 5.40 m |
20 × 20 cabinets 12.00 × 6.75 m |
24 × 24 cabinets 14.40 × 8.10 m |
32 × 32 cabinets 19.20 × 10.80 m |
Fine-pitch Cni and Uni projects may use the 600 × 675 mm cabinet variant for the highest resolutions; the grid math is the same, but the cabinet count changes. Confirm the cabinet drawing before ordering. The table is a planning aid, not a catalogue. Above 4K, the controller, the sending-card count and the frame structure all change, and a 19.2 m wall needs an engineering review before it needs a quotation. The point is that the cabinet count and the pitch are linked: if the budget only allows P2.5, a native 4K wall is 9.6 m wide; if the room is 4.8 m wide, native 4K needs P1.25.
For a dedicated 4K and 8K planning guide, including cabinet counts for native resolution, read the indoor high resolution LED display page.
16:9 grids on CPS and PS cabinets
Not every platform is built on a 16:9 cabinet. The CPS 640 × 480 mm cabinet is 4:3, so a 16:9 wall uses four cabinets across and three down. The PS 1000 × 250 mm strip is 4:1, so a 16:9 wall uses four columns and nine rows. Both are valid; the difference is the wall proportion you can reach and the number of cabinets in the frame.
| Platform | 16:9 grid | Wall size | Resolution examples |
|---|---|---|---|
| CPS 640 × 480 | 4 × 3 cabinets | 2.56 × 1.44 m | 2048 × 1152 at P1.25; 1664 × 936 at P1.5; 1376 × 774 at P1.86; 1024 × 576 at P2.5 |
| PS 1000 × 250 | 4 × 9 cabinets | 4.00 × 2.25 m | 2560 × 1440 at P1.56; 2048 × 1152 at P1.95; 1536 × 864 at P2.6; 1024 × 576 at P3.91 |
| Cni / Uni 600 × 337.5 | 1 × 1 is already 16:9 | 0.60 × 0.3375 m per cabinet | 480 × 270 at P1.25; 384 × 216 at P1.5625; 320 × 180 at P1.875; 240 × 135 at P2.5 |
Example 1
5.12 × 2.88 m CPS wall
- Cabinet: 640 × 480 mm
- Grid: 8 × 6 = 48 cabinets
- Pitch: P1.86
- Resolution: 2752 × 1548
- Area: 14.75 m²
Example 2
4.80 × 2.70 m Cni wall
- Cabinet: 600 × 337.5 mm
- Grid: 8 × 8 = 64 cabinets
- Pitch: P1.25
- Resolution: 3840 × 2160
- Area: 12.96 m²
Example 3
6.00 × 3.00 m PS wall
- Cabinet: 1000 × 250 mm
- Grid: 6 × 12 = 72 cabinets
- Pitch: P1.95
- Resolution: 3072 × 1536
- Area: 18.00 m²
05 · Selection
Which Indoor Modular LED Display Configuration Fits Your Room and Viewing Distance?
The nearest viewer decides the pitch, the opening decides the cabinet, and the runtime decides the packaging. The table below is the short version. It assumes a controlled indoor light level and a screen that is watched, not touched; a high-touch or daylit room moves the packaging decision toward GOB or COB, not necessarily toward a finer pitch.
| Closest viewer | Pitch band | Typical cabinet | Typical rooms | Service |
|---|---|---|---|---|
| 1.2–2.5 m | P1.25–P1.56 | Cni, Uni, CPS | Boardroom, control room, studio desk | Front |
| 2.5–4 m | P1.56–P1.86 | CPS, Cni | Conference, classroom, premium retail | Front |
| 3–6 m | P1.86–P2.5 | CPS, Ehonor | Church front rows, lobby, showroom | Front |
| 6–12 m | P2.5–P3.076 | Ehonor, CPS | Auditorium, hall, church nave | Front |
| 12 m and beyond | P2.5–P3.91 | PS, Ehonor | Large hall, stage, transport concourse | Front |
Two adjustments matter more than the table. First, a camera changes the rule: a broadcast or hybrid-meeting wall often needs a finer pitch and a higher refresh than the human eye alone would require. Second, text changes the rule: a control room showing 10-point labels at 5 m needs a finer pitch than a church showing full-screen video at the same distance. Use the pitch pages for the detailed decision, and use this table only to narrow the shortlist.
Pitch pages for the optical decision
Packaging for the surface decision
06 · Service
How Does Front Maintenance Work on an Indoor Modular LED Display?
Front maintenance means the module comes out from the viewing side. There is no rear door, no service corridor and no need to move the wall away from the wall behind it. For a boardroom with a 60 mm recess, a retail wall on a finished plasterboard partition, or a church screen mounted high above a stage, that difference decides whether a repair takes twenty minutes or a weekend.

The service unit is the module, not the cabinet
A failed module is a field swap. A failed receiving card or power supply is a cabinet-level task, which is why the cabinet needs a labelled map and a small set of spare cards. The practical service plan has three lines: spare modules at 2–5% of the cabinet count, one receiving card per 100 cabinets, and a power-supply set sized to the wall. Write the lines into the bill of materials before the order is packed.
The PS strip cabinet is 20.6 mm deep and weighs 2.4–4.8 kg depending on width; the Ehonor 480 × 320 mm cabinet weighs 3.0 kg; the Cni and Uni 600 × 337.5 mm cabinets are 39.75 mm deep and 4 kg. Lighter cabinets make a high wall easier to install and a single cabinet easier to handle, but they do not remove the need for a flat frame and a consistent locking sequence.
What the site team needs before the first service call
- A cabinet map. Row and column labels on the drawing and on the rear of each cabinet. A fault reported as “third row, fifth column” is a ten-minute job; “somewhere on the left” is not.
- A calibration file. The factory calibration data for the exact modules and receiving cards. A replacement module should be loaded with the matching file, not left at default.
- A spare kit with the same batch. Module brightness and colour can drift between production batches. Order the spares with the wall, not after the first failure.
- A front working method. A suction tool, a clean mat and a safe platform. The module is light, but a screen at 4 m needs the right access equipment.
07 · Installation
How Is an Indoor Modular LED Display Installed on Walls, Niches and Floor Bases?
The cabinet is the installation unit, so the method is chosen before the wall is built. Four methods cover most indoor projects: a flush wall bracket, a recessed niche, a suspended frame and a floor-supported base. Each one changes the frame, the service access and the trim detail, and each one should be drawn before the first cabinet arrives.
Flush wall bracket
Recessed niche
Suspended frame
Floor-supported base


The installation sequence that avoids rework
- Survey the opening and the structure. Record the finished width, height, diagonals, wall type, power location and any obstructions. A 5 mm out-of-square opening becomes a visible trim problem at the end.
- Approve the cabinet map and the frame drawing. Confirm the grid, the service direction, the power drops and the data route. This is the last cheap moment to change the size.
- Fix and level the frame. Use a laser level and check the plane, not just the edges. The cabinet locks cannot correct a twisted frame.
- Hang and lock the cabinets. Work from a corner or from the centre according to the drawing; keep the locking sequence consistent so the seams close evenly.
- Fit the modules, power and data. Label the cabinets, connect the receiving cards, and leave the spare ports accessible.
- Calibrate and hand over. Run the white and grey test patterns, load the calibration file, set brightness and check the controller capacity. Deliver the cabinet map, wiring plan, test record and spare list.
08 · Applications
Where Does an Indoor Modular LED Display Deliver the Most Value?
The modular format pays back wherever the room is irregular, the wall has to be serviced from the front, or the screen is likely to change. The seven applications below are the ones where those conditions appear most often. Each card names a starting configuration; the final cabinet count comes from the opening survey, not from the photo.

Control and dispatch rooms

Boardrooms and meeting rooms

Retail and showrooms

Churches and auditoriums

Exhibitions and experience centres

Broadcast and hybrid studios

Hotels and ballrooms
09 · Comparison
How Does an Indoor Modular LED Display Compare With Fixed-Size and LCD Walls?
The comparison is not “LED versus LCD” in the abstract. It is a question of how the screen will be sized, serviced and changed over its life. A fixed-size LED wall and a modular indoor LED display can look identical on commissioning day; they diverge when the room is renovated, a module fails, or the content changes from 16:9 video to a wider canvas.
| Decision | Indoor modular LED display | Fixed-size indoor LED wall | LCD video wall |
|---|---|---|---|
| Size and ratio | Any whole-cabinet grid; ultra-wide, portrait or irregular | Usually planned as one opening; changes need a new frame | Fixed 46–55 inch tiles; visible bezels at every joint |
| Service unit | Module from the front; cabinet stays on the frame | Module or cabinet, depending on the build | Whole panel or tile; often a lift or removal |
| Expansion | Add cabinets of the same series and batch | Replace the wall or rebuild the frame | Add tiles only if the processor and structure allow |
| Seam | No bezel; seams controlled by cabinet flatness | No bezel; same flatness rule | Visible bezel at every tile edge |
| Brightness | 600–800 nits typical for indoor | 600–800 nits typical | 400–700 nits typical; lower contrast in daylight |
| Cost at small size | Higher per square metre than LCD tiles | Similar to modular at the same pitch | Usually lower for a 2 × 2 or 3 × 3 wall |
| Cost at large size | Competitive; cabinet and structure dominate | Competitive; less flexibility | Rises with tile count, processors and mounting |
A modular wall is not automatically cheaper than a fixed-size wall. At the same pitch and cabinet count, the display package is similar; the modular premium appears in the frame, the spare plan and the engineering time. What the premium buys is the ability to change the wall without replacing it. For a room that will be renovated, a brand that refreshes its environment every few years, or a church that adds side screens later, that option has a real value. For a one-off 16:9 wall in a room that will never change, a fixed-size build can be the more efficient choice.
Against a fixed-size LED wall
Against an LCD video wall
10 · Cost
What Does an Indoor Modular LED Display Cost in 2026?
An indoor modular LED display is quoted as a configuration, not a single rate. The display package is the largest line, but the control system, frame, freight, installation and spares change the total. Two quotes for the same wall can differ because one includes a higher-capacity processor, more spare modules, a heavier steel frame or a longer warranty. The bands below are planning figures for the display package, not quotations.
| Pitch band | 2026 planning range, display package | Typical indoor use |
|---|---|---|
| P1.2–P1.5 | USD 800–1,500 per m² | Control room, premium boardroom, broadcast studio |
| P1.8–P2.5 | USD 400–800 per m² | Church, auditorium, conference, retail feature wall |
| P2.9–P3.9 | USD 200–400 per m² | Large hall, transport concourse, long-distance stage wall |
Three worked examples show how the band translates into a project number. The arithmetic is deliberately simple: area × the band rate. Use it for a budget conversation, then ask for an itemised quote with the cabinet count, the pixel matrix and the scope written out.
CPS · P1.86
5.12 × 2.88 m
- Area: 14.75 m²
- Display package: USD 5,900–11,800
- 48 cabinets, 2752 × 1548
- Excludes control, frame, freight, install
Cni · P1.25
4.80 × 2.70 m
- Area: 12.96 m²
- Display package: USD 10,400–19,400
- 64 cabinets, native 3840 × 2160
- Excludes control, frame, freight, install
PS · P1.95
6.00 × 3.00 m
- Area: 18.00 m²
- Display package: USD 7,200–14,400
- 72 cabinets, 3072 × 1536
- Excludes control, frame, freight, install
What sits outside the display package
| Cost line | What it covers | What to confirm |
|---|---|---|
| Control | Processor, sending card, receiving cards, backup | Model, pixel capacity, spare cards |
| Structure | Wall bracket, steel frame, floor base, trim, curved sections | Drawing, finish, who installs |
| Power and signal | Distribution, 5 V wiring, network, UPS, isolators | Circuit plan, cable schedule, termination |
| Freight and packing | Export packing, Incoterm, insurance, destination charges | Packing type, volume, weight, Incoterm |
| Installation | Labour, access equipment, frame assembly, commissioning | Scope, days, supervision, sign-off |
| Spares and warranty | Spare modules, receiving cards, power supplies, cover | Spare percentage, cover period, response path |
11 · Power and control
How Do You Plan Power, Signal and Control for an Indoor Modular LED Display?
A modular wall is a small electrical system as well as a display. The power draw, the inrush current, the receiving-card count and the processor capacity all have to be planned together. The common failure is not a wrong pitch; it is a wall that reaches the site without enough circuits, enough network ports or enough processor capacity for the promised 4K source.
| Subsystem | Planning rule | What to confirm |
|---|---|---|
| Power | Allow 500–800 W/m² maximum and 165–300 W/m² average for the indoor platforms; plan separate circuits per zone and keep the neutral and earth consistent | Circuit count, breaker size, inrush, UPS scope |
| Data | One Cat6 route per receiving-card chain; keep the run inside the controller’s supported length and leave spare ports | Cable schedule, port count, redundancy |
| Receiving cards | Each card drives a fixed pixel area; count the cabinets and the pixels, rather than the cabinets alone | Card model, pixel capacity, spare cards |
| Processor | Size for the native wall resolution, the number of inputs and any scaling or layers | Model, input count, 4K60 support, backup |
| Calibration | Keep the factory calibration file and the cabinet map with the control documents | File version, who holds it, service access |
For a native 4K wall, the pixel budget is 8.3 million pixels before any scaling. That is within the range of a current NovaStar or Colorlight processor, but the input path, the layer count and the frame rate still have to be checked. For an 8K wall, the controller becomes a project-level decision: multiple processors, a video-wall processor or a media server may be needed, and the quotation should show the signal chain rather than only the screen.
Control system selection
Power supply selection
12 · Projects
Which Indoor Modular LED Display Projects Has Excel LED Delivered?
The deployment record matters more than a render. The six cards below show the patterns Excel LED builds most often: a UK church with a wide stage wall, a German conference room planned as a reference configuration, a UAE retail reference, and three African church installations with different cabinet counts. Reference cards are labelled as references; they are not presented as named clients.

UK church reference

Berlin conference room reference

Dubai retail atrium reference

South Africa church wall

Tema church, 11.7 m²

Lagos multi-screen church
13 · Factory
How Is an Indoor Modular LED Display Tested and Packed Before Shipping?
A modular wall leaves the factory as a set of cabinets, modules and control parts, not as a single box. The quality risk sits in the interfaces: the module-to-cabinet fit, the cabinet-to-cabinet lock, the calibration file and the packing. The photos below are from the Excel LED production and dispatch process; ask any supplier for the same evidence at the exact cabinet and pitch you are buying.




Six checks to write into the order
- Module fit and flatness. Every module sits flush with its neighbours; the cabinet is checked on a surface plate before packing.
- Cabinet lock and seam line. A trial assembly of at least one row confirms that the locks close and the seams stay even.
- White and grey uniformity. The wall is run at low brightness, not just at full output, because low-grey uniformity is harder to hold.
- Calibration file. The file is saved, versioned and matched to the cabinet map. A spare module without the file is only half a spare.
- Control and signal test. The exact processor, sending card and receiving cards are tested together at the native resolution.
- Packing and labelling. Each cabinet is labelled with its row and column; the packing list matches the drawing. A missing label becomes a site puzzle.
Certificates are configuration-specific. Ask for the CE and RoHS documentation for the exact cabinet, module and power supply, plus the ISO 9001 quality-management scope where the project requires it. The Excel LED manufacturing process page describes the production route in more detail.
14 · Maintenance
How Do You Maintain and Expand an Indoor Modular LED Display?
Maintenance on a modular wall is mostly routine, plus a small number of module swaps. The routine is cleaning, brightness checks and a look at the cabinet map after any work near the wall. The non-routine is a failed module, card or power supply. Both are easier when the wall was specified with spares and labels, which is a purchasing decision rather than a service decision.
| Task | Suggested interval | What to record |
|---|---|---|
| Dry clean the front | Monthly in a public room; quarterly in a controlled room | Cloth type, any marks, modules to inspect |
| Check brightness and colour | Every 6 months | Target nits, measured value, uniformity notes |
| Inspect the cabinet map | After any service or building work | Missing labels, loose trim, cable route changes |
| Test the spare kit | Every 12 months | Module, card and power-supply condition |
| Review the calibration file | After a module swap | File version, module batch, who loaded it |
Expanding the wall without changing its look
An indoor modular LED display can be extended when the original frame, control capacity and production batch allow it. Three conditions make an extension practical. First, the same cabinet series and module batch should be available; brightness and colour can drift between batches, so a later addition may need a calibration pass. Second, the frame must be designed for the larger load, or the extension needs its own frame. Third, the processor must have spare pixel capacity and the receiving-card chain must have spare ports. Plan all three at the first order if an extension is likely.
15 · FAQ
What Do Buyers Ask Most About an Indoor Modular LED Display?
Can indoor modular LED displays be made in custom sizes?
What is the difference between an LED module and an LED cabinet?
Which pixel pitch is best for an indoor modular LED display?
Can an indoor modular LED display be maintained from the front?
Can I expand the screen later?
Do you supply the control system and installation guidance?
How do I calculate the resolution of a custom wall?
Which cabinet size should I choose: 1000 × 250, 640 × 480 or 600 × 337.5 mm?
Can an indoor modular LED display be curved or irregular?
How long is production and shipping?
What warranty and spare parts are included?
How much does an indoor modular LED display cost per square metre?
16 · Next step
How Do You Request an Indoor Modular LED Display Configuration?
A useful configuration request is short and specific. Send five things: the finished opening width and height, the closest viewer distance, the target resolution or content type, the installation method, and the destination country. With those, the factory can return a cabinet map, a pitch recommendation, a control configuration and an itemised price without a round of guesswork.
01 · Send the room
02 · Receive the map
03 · Approve and build
For a broader view of the indoor range, start at the indoor LED screen collection or the LED display manufacturer home page. For a pitch-specific comparison, use the P1.5, P1.8, P2 and P2.5 pages linked above. For the system theory behind the cabinet grid, read the modular LED display system guide.
17 · Resources
Which Indoor Modular LED Display Resources Should You Read Next?
The pages below answer the questions this article does not try to repeat. Use the collection pages for the product range, the pitch pages for the optical decision, and the guides for the engineering detail behind the cabinet map.
Ready to Plan an Indoor Modular LED Display?
Send the opening, the closest viewer distance and the target resolution. The reply will include a cabinet map, a pitch recommendation, the control configuration and an itemised price. No obligation, no generic brochure.