Indoor modular LED display video wall in an executive boardroom with a custom-width screen

Indoor modular LED display · 5 cabinet platforms · P0.625–P3.91 mm

Indoor Modular LED Display for Custom-Size Video Walls

An indoor modular LED display is a direct-view video wall assembled from standard LED modules and cabinets, so the finished screen follows the room instead of a fixed panel size. Excel LED manufactures five cabinet platforms, from a 1000 × 250 mm strip to a 600 × 337.5 mm 16:9 cabinet, and configures the modules, power, receiving cards and control as one package. This page explains how the system is built, how to calculate a custom size, which platform fits your room, and what a configuration costs in 2026.

5 cabinet formatsP0.625–P3.91Front serviceSMD, GOB, COBCustom to the module grid2-year factory warranty

01 · Definition

What Is an Indoor Modular LED Display and How Is It Built?

An indoor modular LED display is a direct-view video wall built from interchangeable LED modules mounted in standard cabinets. The module is the smallest replaceable pixel block; the cabinet is the structural and service unit; the cabinet grid defines the final width, height and aspect ratio. Because the wall is assembled rather than ordered as one sealed panel, a project can be sized to the opening, extended later and repaired one module at a time.

Quick answer: specify an indoor modular LED display when the opening is not a standard 16:9 rectangle, when the wall may need to grow, or when a failed module has to be replaced from the front without removing the screen. The cabinet grid sets the size; the pixel pitch sets resolution and the closest comfortable viewing distance.

The word modular describes the mechanical system, not a picture-quality grade. A P1.25 modular wall and a P1.25 fixed-size wall can use the same pitch and the same LED lamps. What changes is how the wall is divided, transported, installed and serviced. Buyers should compare the module format, cabinet format, service direction and control capacity, rather than the pitch alone.

Three phrases appear in project briefs and searches: a modular indoor LED video wall is the finished assembly, indoor LED display modules are the replaceable pixel blocks, and modular LED screen panels usually means the cabinets. They describe the same stack at different levels. When a specification uses one term without the other two, ask which unit is being quoted.

In one sentence: an indoor modular LED display is a video wall whose final size is set by a grid of standard cabinets, not by a factory-sealed panel. That is what makes custom sizing, later expansion and front-service repair possible.

The module sets the repair unit

A module carries the LEDs, driver ICs and connectors for one pixel block. If a module fails, the field task is a module swap, not a wall replacement. The module size and pitch together decide how many pixels sit on that block and how precisely the seam can be set.

The cabinet sets the structural grid

The cabinet holds a fixed group of modules, carries the power supply and receiving card, and provides the locking edges that keep the wall flat. Its width and height become the step size of the finished screen: every size you can build is a multiple of the cabinet, not an arbitrary millimetre.

The control system sets the pixel budget

A sending card or processor has a maximum pixel capacity, and each receiving card drives a fixed area. The cabinet count and pitch decide whether the wall fits inside that capacity at 60 Hz, with or without redundancy. This is why a quote that lists only “P2.5 panels” is incomplete.

The wall is the geometry decision

Width, height, aspect ratio, corners and openings are chosen before production. The factory turns those dimensions into a cabinet map, a cut list and a resolution matrix. Changing the opening after the frame is built is possible, but it is a new engineering task, not a menu option.
Modular is not the same as fixed-size. A fixed-size indoor wall is also built from cabinets, but it is planned as one complete unit for one opening. A modular indoor wall is planned as a system that can be extended, re-configured or partly replaced. For the fixed-install route, compare the indoor fixed LED display range; for the modular route, the cabinet grid below is the starting point.

For a supplier-neutral explanation of the full system stack, including modules, cabinets, power supplies, receiving cards and sending cards, read the modular LED display system guide. This page stays on the indoor product, the cabinet platform and the size calculation, so the two pages answer different questions.

02 · Architecture

How Do LED Modules, Cabinets and Control Fit Together in an Indoor Modular LED Display?

Four layers make the system, and each one fixes a different decision. The table below is the quickest way to see where a specification can go wrong: a project can have the right pitch and the wrong cabinet, or the right cabinet and a controller that cannot drive the pixel count.

Layer What it fixes Excel LED example
LED module Pixel block, repair granularity, spare-part size 250 × 250 mm on PS; 320 × 160 mm on Ehonor and CPS; 150 × 168.75 mm on fine-pitch Cni and Uni builds
Cabinet Wall geometry, structural depth, service direction 1000 × 250 mm, 750 × 250 mm and 500 × 250 mm on PS; 640 × 480 mm on CPS; 600 × 337.5 mm on Cni and Uni; 480 × 320 mm on Ehonor; 320 × 480 mm on Ehonor Pro
Power and data Reliability, heat and the per-cabinet pixel area 5 V power supplies and NovaStar receiving cards inside the cabinet; confirm the exact model on the quotation
Control Inputs, scaling, layers and total pixel capacity NovaStar MCTRL or VX sending and processing, or Colorlight X series; capacity chosen from the wall resolution

Each modular LED cabinet carries its own power supply and receiving card, so the cabinet is also the electrical unit. The pixel math is simple and worth doing before any quote is compared. A 320 × 160 mm module at P1.86 carries 172 × 86 pixels, because 320 ÷ 1.86 is 172 and 160 ÷ 1.86 is 86. A 640 × 480 mm CPS cabinet holds two modules across and three down, so the cabinet itself is 344 × 258 pixels. Multiply by the cabinet count and you have the native resolution of the wall.

Technician removing a front-service LED module from an indoor modular LED display with a suction tool
A front-service module comes out of the finished wall with a suction tool. The cabinet stays on the frame, which is the practical difference between a modular wall and a sealed panel.
Rear view of a 640 x 480 mm indoor LED cabinet showing the die-cast frame, power supply and receiving card
The rear of a 640 × 480 mm cabinet: die-cast frame, power supply, receiving card and the module mounting points. Depth and weight, rather than the front look alone, decide the wall structure.

Why the cabinet format matters more than the cabinet colour

Three cabinet decisions affect the project more than any finish option. The first is depth: the PS strip cabinet is 20.6 mm deep, which lets it sit in a shallow recess where a 70 mm Ehonor cabinet would not fit. The second is weight: a 1000 × 250 mm PS cabinet weighs 4.8 kg, the 750 mm version 3.6 kg and the 500 mm version 2.4 kg, and an Ehonor 480 × 320 mm cabinet weighs 3.0 kg. The third is flatness: the locking edges and the frame behind them decide whether the seams disappear at arm’s length.

A thin cabinet is not automatically the better choice. A shallow cabinet has less room for the power supply and the receiving card, and it may need a flatter wall behind it. A deeper cabinet is easier to service and often easier to set level on a steel frame. The right answer depends on the opening, the structure and the service direction, which is why the platform table below is organized by geometry rather than by price.

03 · Platforms

Which Indoor Modular LED Display Cabinet Platforms Does Excel LED Offer?

Excel LED builds five cabinet formats for indoor modular LED displays. They are not interchangeable price tiers; each one solves a different geometry or structure problem. A strip cabinet makes an ultra-wide wall or a shallow recess practical, a 16:9 cabinet makes a native 4K grid simple, and a lightweight 480 × 320 cabinet keeps a wall-mounted room within the structure’s budget.

Platform Module Cabinet Depth / weight Pitch range Best for
PS Series / PS Pro 250 × 250 mm 1000 × 250, 750 × 250, 500 × 250 mm 20.6 mm; 2.4–4.8 kg P1.56–P3.91 Ultra-wide walls, shallow recesses, strip and ribbon screens
Ehonor 320 × 160 mm 480 × 320 mm 70 mm; 3.0 kg P1.25–P3.076 Lightweight wall-mounted rooms, retail and conference
Ehonor Pro / Pro Max 320 × 160 mm 320 × 480 mm portrait Confirm in quotation P1.25–P3.076 Portrait columns, narrow bays, SMD or COB builds
CPS / CPS Pro / Pro Max 320 × 160 mm 640 × 480 mm Confirm in quotation P1.2–P3 16:9 in a 4 × 3 cabinet grid; conference, control and retail
Cni / Uni 150 × 168.75 mm fine pitch; 320 × 160 mm wider builds 600 × 337.5 mm 39.75 mm; 4 kg P0.625–P1.875 Native 4K and 8K grids, premium boardrooms and control rooms

One dimensional note: some fine-pitch Cni and Uni builds use a 600 × 675 mm cabinet rather than the 16:9 600 × 337.5 mm format. The pixel math is the same, but the row count changes, so confirm the cabinet drawing for the exact pitch. The cabinet size is a mechanical decision; the pitch is an optical one. The same 600 × 337.5 mm cabinet can be built at P1.25 for a control room or at P1.875 for a larger room with a longer viewing distance. Decide the geometry first, then the pitch, then the packaging. Reversing that order is how projects end up with a screen that fits the budget but not the wall.

PS Series 1000 x 250 mm ultra-slim indoor modular LED cabinet
Strip format · 1000 × 250 mm

PS Series

A 20.6 mm aluminium-profile cabinet in 1000, 750 and 500 mm widths. The 1000×250 mm modular indoor LED cabinet is the standard strip; it makes ultra-wide walls, ribbon screens and shallow recesses possible, and a 4 × 9 cabinet grid gives a 16:9 canvas. Front service and 2.4–4.8 kg per cabinet keep a large wall manageable on site.
P1.56–P3.91600 nits3,840 Hz20.6 mm2.4–4.8 kg
Ehonor 480 x 320 mm indoor modular LED cabinet with front-service modules
Lightweight · 480 × 320 mm

Ehonor Series

A 3.0 kg, 70 mm cabinet with a 320 × 160 mm module and a 160° viewing angle. It covers P1.25–P3.076 and is the usual choice for a wall-mounted conference room, retail feature wall or church balcony where the structure has to stay light and the service access is from the front.
P1.25–P3.076600–800 nits3.0 kg70 mmFront service
CPS 640 x 480 mm indoor small pitch LED cabinet for modular video walls
16:9 grid · 640 × 480 mm

CPS Series

A 640 × 480 mm cabinet with a 320 × 160 mm module. Four cabinets across and three down make a 16:9 wall, which is why CPS is the common route for conference rooms, control desks and retail walls. SMD CPS, GOB CPS Pro and COB CPS Pro Max share the same cabinet format, so the packaging can change without changing the frame.
P1.2–P3800 nits3,840 / 1,920 Hz800 / 300 W/m²Front service
cob led screen-Cni
COB · 600 × 337.5 mm

Cni Series

A 600 × 337.5 mm, 39.75 mm COB cabinet with a 4 kg body and a 16:9 ratio. The fine-pitch build reaches P0.625, and the 600 mm width makes native 4K and 8K grids easy to count: eight cabinets across and eight down at P1.25 is 3840 × 2160. Cni is the value route into a COB modular wall.
P0.625–P1.875600 nits4 kg39.75 mmCOB front
cob led screen-Uni
Fine pitch · 600 × 337.5 mm

Uni Series

The same 600 × 337.5 mm format with the fine-pitch COB configuration and optional dual backup. At P1.25 the cabinet is 480 × 270 pixels; 8 × 8 cabinets give a native 3840 × 2160 wall on a 4.8 × 2.7 m frame. Uni is the platform to start from when the room has to show native 4K or 8K content, not merely accept a 4K input.
P0.625–P1.875600 nits4 kg39.75 mmDual backup option

Two related formats sit beside the five main platforms. The Ehonor Pro 320 × 480 mm portrait cabinet is useful for columns and narrow bays, while the Ehonor Pro Max COB version adds a sealed front for high-touch rooms. For a broader view of the indoor range, start at the indoor LED screen collection.

04 · Sizing

How Do You Size a Custom Indoor Modular LED Display and Calculate Resolution?

Start with the opening, not with a diagonal or a brochure size. The wall is a whole number of cabinets in both directions, so the first job is to find the cabinet grid that fills the opening with the smallest unused margin. Then choose the pitch that gives the resolution and viewing distance the room needs. This is the same calculation behind any custom-size indoor LED display quotation, whether the brief calls it a modular wall or a custom LED screen. The sequence is mechanical, and it prevents the two most common mistakes: a screen that misses the opening by 40 mm, and a 4K content plan that lands on a 2.5K wall.

The three numbers you need before asking for a quote

  • Opening width and height in millimetres. Measure the finished opening, not the old screen. Note any skirting, door swing, ceiling bulkhead or service hatch that limits the frame.
  • Closest viewer distance. The nearest seat, not the back of the room. Minimum comfortable distance is roughly the pitch in millimetres expressed in metres: P1.86 is about 1.9 m, P2.5 about 2.5 m.
  • Content and target resolution. A native 1920 × 1080 wall, a 3840 × 2160 wall and an ultra-wide 32:9 wall lead to different cabinet counts even when the area is the same.

Resolution targets on a 600 × 337.5 mm cabinet

Target resolution P1.25 P1.5625 P1.875 P2.5
1920 × 1080 4 × 4 cabinets
2.40 × 1.35 m
5 × 5 cabinets
3.00 × 1.69 m
6 × 6 cabinets
3.60 × 2.03 m
8 × 8 cabinets
4.80 × 2.70 m
3840 × 2160 8 × 8 cabinets
4.80 × 2.70 m
10 × 10 cabinets
6.00 × 3.38 m
12 × 12 cabinets
7.20 × 4.05 m
16 × 16 cabinets
9.60 × 5.40 m
7680 × 4320 16 × 16 cabinets
9.60 × 5.40 m
20 × 20 cabinets
12.00 × 6.75 m
24 × 24 cabinets
14.40 × 8.10 m
32 × 32 cabinets
19.20 × 10.80 m

Fine-pitch Cni and Uni projects may use the 600 × 675 mm cabinet variant for the highest resolutions; the grid math is the same, but the cabinet count changes. Confirm the cabinet drawing before ordering. The table is a planning aid, not a catalogue. Above 4K, the controller, the sending-card count and the frame structure all change, and a 19.2 m wall needs an engineering review before it needs a quotation. The point is that the cabinet count and the pitch are linked: if the budget only allows P2.5, a native 4K wall is 9.6 m wide; if the room is 4.8 m wide, native 4K needs P1.25.

For a dedicated 4K and 8K planning guide, including cabinet counts for native resolution, read the indoor high resolution LED display page.

16:9 grids on CPS and PS cabinets

Not every platform is built on a 16:9 cabinet. The CPS 640 × 480 mm cabinet is 4:3, so a 16:9 wall uses four cabinets across and three down. The PS 1000 × 250 mm strip is 4:1, so a 16:9 wall uses four columns and nine rows. Both are valid; the difference is the wall proportion you can reach and the number of cabinets in the frame.

Platform 16:9 grid Wall size Resolution examples
CPS 640 × 480 4 × 3 cabinets 2.56 × 1.44 m 2048 × 1152 at P1.25; 1664 × 936 at P1.5; 1376 × 774 at P1.86; 1024 × 576 at P2.5
PS 1000 × 250 4 × 9 cabinets 4.00 × 2.25 m 2560 × 1440 at P1.56; 2048 × 1152 at P1.95; 1536 × 864 at P2.6; 1024 × 576 at P3.91
Cni / Uni 600 × 337.5 1 × 1 is already 16:9 0.60 × 0.3375 m per cabinet 480 × 270 at P1.25; 384 × 216 at P1.5625; 320 × 180 at P1.875; 240 × 135 at P2.5

Example 1

5.12 × 2.88 m CPS wall

  • Cabinet: 640 × 480 mm
  • Grid: 8 × 6 = 48 cabinets
  • Pitch: P1.86
  • Resolution: 2752 × 1548
  • Area: 14.75 m²

Example 2

4.80 × 2.70 m Cni wall

  • Cabinet: 600 × 337.5 mm
  • Grid: 8 × 8 = 64 cabinets
  • Pitch: P1.25
  • Resolution: 3840 × 2160
  • Area: 12.96 m²

Example 3

6.00 × 3.00 m PS wall

  • Cabinet: 1000 × 250 mm
  • Grid: 6 × 12 = 72 cabinets
  • Pitch: P1.95
  • Resolution: 3072 × 1536
  • Area: 18.00 m²
A custom size is not a custom cabinet. The factory does not cut a cabinet to your millimetre; it chooses the cabinet grid that fits your opening. If the opening is 5,000 mm wide, a 640 mm cabinet leaves a 520 mm margin or needs a filler; a 600 mm cabinet leaves a 200 mm margin. The drawing shows the difference before production, which is why the opening survey matters more than the screen photo.

05 · Selection

Which Indoor Modular LED Display Configuration Fits Your Room and Viewing Distance?

The nearest viewer decides the pitch, the opening decides the cabinet, and the runtime decides the packaging. The table below is the short version. It assumes a controlled indoor light level and a screen that is watched, not touched; a high-touch or daylit room moves the packaging decision toward GOB or COB, not necessarily toward a finer pitch.

Closest viewer Pitch band Typical cabinet Typical rooms Service
1.2–2.5 m P1.25–P1.56 Cni, Uni, CPS Boardroom, control room, studio desk Front
2.5–4 m P1.56–P1.86 CPS, Cni Conference, classroom, premium retail Front
3–6 m P1.86–P2.5 CPS, Ehonor Church front rows, lobby, showroom Front
6–12 m P2.5–P3.076 Ehonor, CPS Auditorium, hall, church nave Front
12 m and beyond P2.5–P3.91 PS, Ehonor Large hall, stage, transport concourse Front

Two adjustments matter more than the table. First, a camera changes the rule: a broadcast or hybrid-meeting wall often needs a finer pitch and a higher refresh than the human eye alone would require. Second, text changes the rule: a control room showing 10-point labels at 5 m needs a finer pitch than a church showing full-screen video at the same distance. Use the pitch pages for the detailed decision, and use this table only to narrow the shortlist.

Pitch pages for the optical decision

Compare the P1.5 indoor LED display, P1.8 indoor LED display, P2 indoor LED display and P2.5 indoor LED display pages. Each one covers the module resolution, cabinet count and viewing distance for that pitch.

Packaging for the surface decision

SMD is the value route; GOB adds a glue layer for high-touch rooms; COB seals the die under resin for close viewing and frequent cleaning. The indoor COB LED display page compares the three on a five-year cost basis, and the COB LED screen for indoor collection lists the series.

06 · Service

How Does Front Maintenance Work on an Indoor Modular LED Display?

Front maintenance means the module comes out from the viewing side. There is no rear door, no service corridor and no need to move the wall away from the wall behind it. For a boardroom with a 60 mm recess, a retail wall on a finished plasterboard partition, or a church screen mounted high above a stage, that difference decides whether a repair takes twenty minutes or a weekend.

600 x 337.5 mm indoor modular LED cabinet with modules removed for front service
A 600 × 337.5 mm cabinet with modules removed: the power supply, receiving card and module connectors stay accessible from the front. Keep two spare modules per 100 cabinets on site for the first year.

The service unit is the module, not the cabinet

A failed module is a field swap. A failed receiving card or power supply is a cabinet-level task, which is why the cabinet needs a labelled map and a small set of spare cards. The practical service plan has three lines: spare modules at 2–5% of the cabinet count, one receiving card per 100 cabinets, and a power-supply set sized to the wall. Write the lines into the bill of materials before the order is packed.

The PS strip cabinet is 20.6 mm deep and weighs 2.4–4.8 kg depending on width; the Ehonor 480 × 320 mm cabinet weighs 3.0 kg; the Cni and Uni 600 × 337.5 mm cabinets are 39.75 mm deep and 4 kg. Lighter cabinets make a high wall easier to install and a single cabinet easier to handle, but they do not remove the need for a flat frame and a consistent locking sequence.

What the site team needs before the first service call

  • A cabinet map. Row and column labels on the drawing and on the rear of each cabinet. A fault reported as “third row, fifth column” is a ten-minute job; “somewhere on the left” is not.
  • A calibration file. The factory calibration data for the exact modules and receiving cards. A replacement module should be loaded with the matching file, not left at default.
  • A spare kit with the same batch. Module brightness and colour can drift between production batches. Order the spares with the wall, not after the first failure.
  • A front working method. A suction tool, a clean mat and a safe platform. The module is light, but a screen at 4 m needs the right access equipment.

07 · Installation

How Is an Indoor Modular LED Display Installed on Walls, Niches and Floor Bases?

The cabinet is the installation unit, so the method is chosen before the wall is built. Four methods cover most indoor projects: a flush wall bracket, a recessed niche, a suspended frame and a floor-supported base. Each one changes the frame, the service access and the trim detail, and each one should be drawn before the first cabinet arrives.

Flush wall bracket

A steel bracket fixed to the structural wall, with the cabinets hung and locked in sequence. The most common method for boardrooms, retail walls and church side walls. The finished screen sits 20–70 mm off the wall depending on the cabinet; front service means no rear clearance is required.

Recessed niche

The screen sits inside a prepared opening so the front is flush with the finished wall. The PS 20.6 mm strip is the usual choice for a shallow niche; the opening must include ventilation and a removable trim for service. Confirm the niche depth against the cabinet depth, not against the module alone.

Suspended frame

A truss or ceiling frame carries the wall above a stage, atrium or concourse. The structure engineer checks the load, the sway and the access for module replacement. Suspended walls often use the lighter Ehonor cabinet and a front-service routine from a platform or lift.

Floor-supported base

A steel base carries the wall from the floor when the wall behind cannot take the load. Common in showrooms, exhibition spaces and rented rooms. The base becomes part of the design, so the drawing has to show the plinth, the cable route and the service access.
Technicians assembling the steel frame for an indoor modular LED display before cabinet installation
The frame is surveyed, levelled and fixed before the first cabinet. The cabinet grid is only as flat as the frame behind it.
Flush-mounted indoor modular LED display with a continuous cabinet grid on a finished wall
A flush wall after commissioning. The trim, the cable route and the service access are part of the installation drawing, not afterthoughts.

The installation sequence that avoids rework

  1. Survey the opening and the structure. Record the finished width, height, diagonals, wall type, power location and any obstructions. A 5 mm out-of-square opening becomes a visible trim problem at the end.
  2. Approve the cabinet map and the frame drawing. Confirm the grid, the service direction, the power drops and the data route. This is the last cheap moment to change the size.
  3. Fix and level the frame. Use a laser level and check the plane, not just the edges. The cabinet locks cannot correct a twisted frame.
  4. Hang and lock the cabinets. Work from a corner or from the centre according to the drawing; keep the locking sequence consistent so the seams close evenly.
  5. Fit the modules, power and data. Label the cabinets, connect the receiving cards, and leave the spare ports accessible.
  6. Calibrate and hand over. Run the white and grey test patterns, load the calibration file, set brightness and check the controller capacity. Deliver the cabinet map, wiring plan, test record and spare list.

08 · Applications

Where Does an Indoor Modular LED Display Deliver the Most Value?

The modular format pays back wherever the room is irregular, the wall has to be serviced from the front, or the screen is likely to change. The seven applications below are the ones where those conditions appear most often. Each card names a starting configuration; the final cabinet count comes from the opening survey, not from the photo.

Indoor modular LED display video wall in a control room with operator desks and data dashboards

Control and dispatch rooms

A 24/7 wall with multiple sources, small labels and a closest viewer at 2–3 m. The cabinet grid usually follows the desk layout, not a 16:9 frame.
Start with: Cni or Uni P1.25–P1.56, front service, 600–800 nits
Indoor modular LED display covering the front wall of an executive boardroom

Boardrooms and meeting rooms

A flush wall behind the table, often inside a shallow recess. The priority is a clean front, low brightness and a pitch that keeps spreadsheet text sharp.
Start with: CPS or Cni P1.25–P1.86, 600 nits, front service
Curved indoor modular LED display in a retail showroom

Retail and showrooms

A feature wall that follows a brand geometry, often higher than a standard panel and visible from several angles. Custom width matters more than native 4K.
Start with: Ehonor or CPS P1.86–P2.5, 800 nits
Indoor modular LED display in an auditorium with rows of seats

Churches and auditoriums

A wide stage wall with a long viewing distance and a high mounting point. The cabinet grid is often wider than 16:9, and front service avoids scaffolding in the auditorium.
Start with: Ehonor or CPS P2.5–P3.076, front service
Indoor modular LED display used as an exhibition and experience centre backdrop

Exhibitions and experience centres

A temporary or semi-permanent wall that has to be assembled quickly, fit an unusual booth shape and come apart for the next venue. Light cabinets and a labelled map save days.
Start with: Ehonor or PS, P2.5–P3.91, flight-case packing
Curved indoor modular LED display walls in a television broadcast studio

Broadcast and hybrid studios

A camera-facing wall where refresh, moiré and colour consistency matter as much as pitch. A fine-pitch COB surface and a high-refresh driver are the usual starting point.
Start with: Cni or Uni P1.25–P1.56, high refresh, COB
Indoor modular LED display in a hotel ballroom set for a banquet

Hotels and ballrooms

A wide banquet wall that has to look right under chandeliers and camera light, often in a room that also hosts exhibitions and weddings. A modular grid lets the hotel match the ballroom width instead of stacking fixed panels.
Start with: Ehonor or CPS P2.5–P3.076, 800 nits, front service

09 · Comparison

How Does an Indoor Modular LED Display Compare With Fixed-Size and LCD Walls?

The comparison is not “LED versus LCD” in the abstract. It is a question of how the screen will be sized, serviced and changed over its life. A fixed-size LED wall and a modular indoor LED display can look identical on commissioning day; they diverge when the room is renovated, a module fails, or the content changes from 16:9 video to a wider canvas.

Decision Indoor modular LED display Fixed-size indoor LED wall LCD video wall
Size and ratio Any whole-cabinet grid; ultra-wide, portrait or irregular Usually planned as one opening; changes need a new frame Fixed 46–55 inch tiles; visible bezels at every joint
Service unit Module from the front; cabinet stays on the frame Module or cabinet, depending on the build Whole panel or tile; often a lift or removal
Expansion Add cabinets of the same series and batch Replace the wall or rebuild the frame Add tiles only if the processor and structure allow
Seam No bezel; seams controlled by cabinet flatness No bezel; same flatness rule Visible bezel at every tile edge
Brightness 600–800 nits typical for indoor 600–800 nits typical 400–700 nits typical; lower contrast in daylight
Cost at small size Higher per square metre than LCD tiles Similar to modular at the same pitch Usually lower for a 2 × 2 or 3 × 3 wall
Cost at large size Competitive; cabinet and structure dominate Competitive; less flexibility Rises with tile count, processors and mounting

A modular wall is not automatically cheaper than a fixed-size wall. At the same pitch and cabinet count, the display package is similar; the modular premium appears in the frame, the spare plan and the engineering time. What the premium buys is the ability to change the wall without replacing it. For a room that will be renovated, a brand that refreshes its environment every few years, or a church that adds side screens later, that option has a real value. For a one-off 16:9 wall in a room that will never change, a fixed-size build can be the more efficient choice.

Against a fixed-size LED wall

The indoor fixed LED display page covers the fixed-install route: front-service cabinets, 24/7 rooms and a simpler frame. Choose fixed when the opening is final and the budget is tight; choose modular when the screen is part of a changing space.

Against an LCD video wall

The indoor direct view LED display page compares DVLED with LCD and projection on brightness, bezel, service and lifetime. LCD wins on initial cost at small sizes; LED wins on seamlessness, brightness and a service unit that does not require a lift.

10 · Cost

What Does an Indoor Modular LED Display Cost in 2026?

An indoor modular LED display is quoted as a configuration, not a single rate. The display package is the largest line, but the control system, frame, freight, installation and spares change the total. Two quotes for the same wall can differ because one includes a higher-capacity processor, more spare modules, a heavier steel frame or a longer warranty. The bands below are planning figures for the display package, not quotations.

Pitch band 2026 planning range, display package Typical indoor use
P1.2–P1.5 USD 800–1,500 per m² Control room, premium boardroom, broadcast studio
P1.8–P2.5 USD 400–800 per m² Church, auditorium, conference, retail feature wall
P2.9–P3.9 USD 200–400 per m² Large hall, transport concourse, long-distance stage wall

Three worked examples show how the band translates into a project number. The arithmetic is deliberately simple: area × the band rate. Use it for a budget conversation, then ask for an itemised quote with the cabinet count, the pixel matrix and the scope written out.

CPS · P1.86

5.12 × 2.88 m

  • Area: 14.75 m²
  • Display package: USD 5,900–11,800
  • 48 cabinets, 2752 × 1548
  • Excludes control, frame, freight, install

Cni · P1.25

4.80 × 2.70 m

  • Area: 12.96 m²
  • Display package: USD 10,400–19,400
  • 64 cabinets, native 3840 × 2160
  • Excludes control, frame, freight, install

PS · P1.95

6.00 × 3.00 m

  • Area: 18.00 m²
  • Display package: USD 7,200–14,400
  • 72 cabinets, 3072 × 1536
  • Excludes control, frame, freight, install

What sits outside the display package

Cost line What it covers What to confirm
Control Processor, sending card, receiving cards, backup Model, pixel capacity, spare cards
Structure Wall bracket, steel frame, floor base, trim, curved sections Drawing, finish, who installs
Power and signal Distribution, 5 V wiring, network, UPS, isolators Circuit plan, cable schedule, termination
Freight and packing Export packing, Incoterm, insurance, destination charges Packing type, volume, weight, Incoterm
Installation Labour, access equipment, frame assembly, commissioning Scope, days, supervision, sign-off
Spares and warranty Spare modules, receiving cards, power supplies, cover Spare percentage, cover period, response path
Compare the scope, not the rate. A quote at USD 450/m² that excludes the frame, the processor and the spares is not cheaper than a quote at USD 650/m² that includes them. Ask every supplier to price the same cabinet count, the same pitch, the same processor capacity and the same spare list. The indoor LED display price guide explains the cost lines in more detail.

11 · Power and control

How Do You Plan Power, Signal and Control for an Indoor Modular LED Display?

A modular wall is a small electrical system as well as a display. The power draw, the inrush current, the receiving-card count and the processor capacity all have to be planned together. The common failure is not a wrong pitch; it is a wall that reaches the site without enough circuits, enough network ports or enough processor capacity for the promised 4K source.

Subsystem Planning rule What to confirm
Power Allow 500–800 W/m² maximum and 165–300 W/m² average for the indoor platforms; plan separate circuits per zone and keep the neutral and earth consistent Circuit count, breaker size, inrush, UPS scope
Data One Cat6 route per receiving-card chain; keep the run inside the controller’s supported length and leave spare ports Cable schedule, port count, redundancy
Receiving cards Each card drives a fixed pixel area; count the cabinets and the pixels, rather than the cabinets alone Card model, pixel capacity, spare cards
Processor Size for the native wall resolution, the number of inputs and any scaling or layers Model, input count, 4K60 support, backup
Calibration Keep the factory calibration file and the cabinet map with the control documents File version, who holds it, service access

For a native 4K wall, the pixel budget is 8.3 million pixels before any scaling. That is within the range of a current NovaStar or Colorlight processor, but the input path, the layer count and the frame rate still have to be checked. For an 8K wall, the controller becomes a project-level decision: multiple processors, a video-wall processor or a media server may be needed, and the quotation should show the signal chain rather than only the screen.

Control system selection

Start with the LED control system collection for NovaStar, Colorlight, Mooncell, Huidu and RGBlink options. The right model is the one that covers the wall resolution plus the inputs, not the one with the most ports on the brochure.

Power supply selection

The LED display power supply guide covers the 5 V range and the headroom calculation. The power supply is the part most likely to fail in a long-running indoor wall, so it belongs in the spare kit, not just on the bill of materials.

12 · Projects

Which Indoor Modular LED Display Projects Has Excel LED Delivered?

The deployment record matters more than a render. The six cards below show the patterns Excel LED builds most often: a UK church with a wide stage wall, a German conference room planned as a reference configuration, a UAE retail reference, and three African church installations with different cabinet counts. Reference cards are labelled as references; they are not presented as named clients.

Indoor modular LED display in a UK church with a high ceiling and a wide stage wall
United KingdomReference

UK church reference

A high-ceiling church with a wide stage wall, planned so the cabinet grid follows the structural bay rather than a standard 16:9 frame. The front-service routine keeps the wall accessible without scaffolding.
Reference configuration of an indoor modular LED display in a Berlin conference room
GermanyReference

Berlin conference room reference

A 16:9 conference wall with a flush finish and a front-service cabinet grid. The configuration uses a fine-pitch cabinet for text-heavy content at a 4–5 m viewing distance.
Reference configuration of an indoor modular LED display in a Dubai retail atrium
United Arab EmiratesReference

Dubai retail atrium reference

A suspended retail wall seen from several levels, where brightness and a clean front matter more than native 4K. The cabinet grid is sized to the atrium opening, not to a tile count.
Ehonor P2.5 indoor modular LED display at a church in South Africa
South AfricaChurch

South Africa church wall

An Ehonor P2.5 wall in a church auditorium, sized for a long viewing distance and a high mounting point. The lighter 480 × 320 mm cabinet kept the structure simple.
Indoor modular LED display showing graphics at a church in Tema, Ghana
GhanaChurch

Tema church, 11.7 m²

A P2.5 wall at 11.7 m² with a bright stage image and a front-service layout. The project record includes the cabinet count, the pitch and the installation sequence.
Multi-screen indoor modular LED installation in a church auditorium in Lagos, Nigeria
NigeriaChurch

Lagos multi-screen church

A central wall with side screens, planned as one cabinet system so the pitch and brightness match across the room. The layout shows why a modular grid is easier to extend than a fixed panel.

13 · Factory

How Is an Indoor Modular LED Display Tested and Packed Before Shipping?

A modular wall leaves the factory as a set of cabinets, modules and control parts, not as a single box. The quality risk sits in the interfaces: the module-to-cabinet fit, the cabinet-to-cabinet lock, the calibration file and the packing. The photos below are from the Excel LED production and dispatch process; ask any supplier for the same evidence at the exact cabinet and pitch you are buying.

SMT production line at the Excel LED display factory
SMT and driver assembly. The LED lamps, driver ICs and PCB are the first quality gate. Ask for the incoming inspection record and the AOI result for the exact module.
P1.953 rental LED display panels running the 72-hour aging test and calibration racks before packing
Test and calibration racks. Panels are powered on the racks and checked for calibration before packing. A module that fails here does not become a site visit later.
Indoor LED modules under a white test pattern during a factory aging test
Aging under a test pattern. A white and grey pattern exposes dead pixels, colour drift and driver faults that a short functional test can miss.
Export packing and container loading for indoor modular LED display cabinets
Export packing. Flight cases or cartons, corner protection, moisture control and a packing list that matches the cabinet map. Confirm the Incoterm and the insurance before dispatch.

Six checks to write into the order

  • Module fit and flatness. Every module sits flush with its neighbours; the cabinet is checked on a surface plate before packing.
  • Cabinet lock and seam line. A trial assembly of at least one row confirms that the locks close and the seams stay even.
  • White and grey uniformity. The wall is run at low brightness, not just at full output, because low-grey uniformity is harder to hold.
  • Calibration file. The file is saved, versioned and matched to the cabinet map. A spare module without the file is only half a spare.
  • Control and signal test. The exact processor, sending card and receiving cards are tested together at the native resolution.
  • Packing and labelling. Each cabinet is labelled with its row and column; the packing list matches the drawing. A missing label becomes a site puzzle.

Certificates are configuration-specific. Ask for the CE and RoHS documentation for the exact cabinet, module and power supply, plus the ISO 9001 quality-management scope where the project requires it. The Excel LED manufacturing process page describes the production route in more detail.

14 · Maintenance

How Do You Maintain and Expand an Indoor Modular LED Display?

Maintenance on a modular wall is mostly routine, plus a small number of module swaps. The routine is cleaning, brightness checks and a look at the cabinet map after any work near the wall. The non-routine is a failed module, card or power supply. Both are easier when the wall was specified with spares and labels, which is a purchasing decision rather than a service decision.

Task Suggested interval What to record
Dry clean the front Monthly in a public room; quarterly in a controlled room Cloth type, any marks, modules to inspect
Check brightness and colour Every 6 months Target nits, measured value, uniformity notes
Inspect the cabinet map After any service or building work Missing labels, loose trim, cable route changes
Test the spare kit Every 12 months Module, card and power-supply condition
Review the calibration file After a module swap File version, module batch, who loaded it

Expanding the wall without changing its look

An indoor modular LED display can be extended when the original frame, control capacity and production batch allow it. Three conditions make an extension practical. First, the same cabinet series and module batch should be available; brightness and colour can drift between batches, so a later addition may need a calibration pass. Second, the frame must be designed for the larger load, or the extension needs its own frame. Third, the processor must have spare pixel capacity and the receiving-card chain must have spare ports. Plan all three at the first order if an extension is likely.

The cheapest expansion is the one planned before the first shipment. Ask for a cabinet map that shows the future row or column, a frame with a bolted extension point, and a processor sized one step above the current wall. The cost at order time is small; the cost after commissioning is a new engineering project.

15 · FAQ

What Do Buyers Ask Most About an Indoor Modular LED Display?

Can indoor modular LED displays be made in custom sizes?
Yes, within the cabinet grid. The width and height are whole-number multiples of the cabinet, so the factory will not cut a cabinet to an arbitrary millimetre. Send the finished opening and the closest viewing distance; the reply should be a cabinet map with the exact wall size, the resolution and the unused margin. A 5,000 mm opening, for example, can be filled with seven 640 mm cabinets plus a 520 mm filler, or with eight 600 mm cabinets plus a 200 mm filler.
What is the difference between an LED module and an LED cabinet?
The module is the smallest replaceable pixel block; the cabinet is the structural and service unit that holds several modules plus the power supply and receiving card. A module swap is a short front-service task. A cabinet swap is a larger task that involves the frame, the power and the data chain. When a supplier quotes a wall, ask for both the module size and the cabinet size, rather than the pitch alone.
Which pixel pitch is best for an indoor modular LED display?
Start from the closest viewer. P1.25–P1.56 suits a boardroom, control room or studio where people sit within 2.5 m; P1.56–P1.86 suits a conference room or premium retail wall at 2.5–4 m; P1.86–P2.5 suits a church front row, lobby or showroom at 3–6 m; P2.5–P3.076 suits a long hall or auditorium. A camera or small text pushes the choice one step finer.
Can an indoor modular LED display be maintained from the front?
Yes. The indoor platforms in this article are front-service: a suction tool removes the module from the viewing side, and the cabinet stays on the frame. That means no rear corridor and no need to move the wall away from the wall behind it. Confirm the service direction in the quotation, because a rear-service cabinet in a shallow niche is a maintenance problem waiting to happen.
Can I expand the screen later?
Often, if the first order is planned for it. The same cabinet series and module batch should be available, the frame should have an extension point, and the processor should have spare pixel capacity. Adding a column or a row is straightforward when those three conditions are met; adding a different cabinet series is effectively a new wall. Say at the first order that an extension is possible.
Do you supply the control system and installation guidance?
Yes. Excel LED supplies the processor, sending card, receiving cards and power supplies, and provides a cabinet map, wiring plan and commissioning checklist with the order. For on-site installation, the scope can include remote guidance or a factory technician, depending on the destination and the project. The quotation should state exactly what is supplied and what the local installer is expected to do.
How do I calculate the resolution of a custom wall?
Divide the module width and height by the pitch to get the module pixels, then multiply by the number of modules in the cabinet and the number of cabinets in the wall. For example, a 320 × 160 mm module at P1.86 is 172 × 86 pixels; a 640 × 480 mm cabinet with two modules across and three down is 344 × 258 pixels; an 8 × 6 cabinet wall is 2752 × 1548 pixels. The calculation is exact only when the module and cabinet dimensions divide cleanly by the pitch.
Which cabinet size should I choose: 1000 × 250, 640 × 480 or 600 × 337.5 mm?
Use 1000 × 250 mm for an ultra-wide or shallow strip wall, 640 × 480 mm for a familiar 16:9 grid in four-across, three-down cabinets, and 600 × 337.5 mm when you want a 16:9 cabinet with a direct route to native 4K or 8K. The cabinet is a mechanical choice; the pitch is an optical one. Decide the opening and the platform first, then choose the pitch.
Can an indoor modular LED display be curved or irregular?
A flat cabinet grid can be stepped, stacked or combined with custom frame sections to follow a room, and some series support curved builds. A true curve needs the cabinet and module geometry to be designed for it, not a flat cabinet forced into a curve. Send the plan view, the minimum radius and the service access; the factory will confirm which platform can be built that way.
How long is production and shipping?
Production time depends on the cabinet count, the pitch, the packaging and the control configuration. A standard indoor order is typically several weeks from drawing approval, followed by sea or air freight. The quotation should state the production lead time, the Incoterm and the estimated transit time separately, so a delay at one stage is visible rather than hidden in a single delivery date.
What warranty and spare parts are included?
The standard factory warranty is two years, with spare modules, receiving cards and power supplies available for the project. For a 24/7 room, agree the spare percentage (2–5% of modules), the card count and the response path before packing. A replacement module should be loaded with the matching calibration file; without it, the spare may be visible in a low-grey test pattern.
How much does an indoor modular LED display cost per square metre?
For early planning, the display package is roughly USD 800–1,500/m² at P1.2–P1.5, USD 400–800/m² at P1.8–P2.5 and USD 200–400/m² at P2.9–P3.9. Those figures include cabinets, modules, power supplies and receiving cards; they exclude control, structure, freight, installation and spares. Send the opening, the closest viewer and the target resolution for an itemised configuration price.

16 · Next step

How Do You Request an Indoor Modular LED Display Configuration?

A useful configuration request is short and specific. Send five things: the finished opening width and height, the closest viewer distance, the target resolution or content type, the installation method, and the destination country. With those, the factory can return a cabinet map, a pitch recommendation, a control configuration and an itemised price without a round of guesswork.

01 · Send the room

A photo of the wall, the opening dimensions and the nearest seat. If there is a drawing, send it; a dimensioned sketch is better than a phone photo alone.

02 · Receive the map

A cabinet map with the wall size, resolution, cabinet count, pitch and service direction. The drawing shows the unused margin before you commit.

03 · Approve and build

Approve the drawing, the control configuration and the spare list. Production starts after the drawing is signed, not after a price is agreed verbally.

For a broader view of the indoor range, start at the indoor LED screen collection or the LED display manufacturer home page. For a pitch-specific comparison, use the P1.5, P1.8, P2 and P2.5 pages linked above. For the system theory behind the cabinet grid, read the modular LED display system guide.

Ready to Plan an Indoor Modular LED Display?

Send the opening, the closest viewer distance and the target resolution. The reply will include a cabinet map, a pitch recommendation, the control configuration and an itemised price. No obligation, no generic brochure.

Scroll to Top

Contact Us Now!

Thank You for Your Inquiry!

 Our LED display expert will contact you within 12 hours.

You can also contact us directly: +86 18569492693 ;excelledscreens@gmail.com